Beijing Reci Laser Technology Co., Ltd
User Guide for FCA Series Hand Laser Welding System
14
3.4.2
Requirement of the cooling system
The laser adopts air-cooled heat dissipation. When selecting the placement position, please
operate in a non closed and narrow space with good air circulation conditions. Do not place any
objects that may block the exhaust on the top of the machine. The air flow direction is shown in the
following figure:
Fig. 3.3.2a schematic diagram of air inlet and exhaust
The requirements for laser placement space are shown in the figure below
:
Figure 3.3.2b laser placement space requirements
Note: the filter screens of the two air inlets must be cleaned regularly. The equipment damage
caused by improper use / maintenance will not be guaranteed.
3.5
Installation precautions
(1)
The laser need to be placed horizontally and fixed, without inversion, side setting,
vibration and impact.
(2)
When connecting the power line and control line, make sure that the power supply is
disconnected for non live operation.