Beijing Reci Laser Technology Co., Ltd
User Guide for Single Module Fiber Laser
28
4.5 Laser Control
The power supply of the fiber laser is powered by local and remote methods.
The local mode is controlled by the front panel START button, and the remote mode
is controlled by the REM_START signal line in the rear panel CTRL_INTERFACE.
The laser power setting and the light-emission enable control: the laser power
setting is controlled by the 0~10V analog signal on the rear panel, the light-emission
enable control is controlled by the LASER_EN signal line of CTRL_INTERFACE in
the rear panel. In addition, the output is controlled by the MOD_SW signal of
CTRL_INTERFACE in the rear panel.
4.6 Local AD Mode
4.6.1
Settings and Connections
Figure 4.7 the connection for local AD model
(1)Set the AD mode with the control software.
(2)The 24V Laser enable signal is connected to pins 5 and 6 of the rear panel
16PIN CTRL_INTERFACE.
(3)The 24V modulated signal is connected to pins 12 and 13 in the rear panel 16
PIN CTRL_INTERFACE.