Beijing Reci Laser Technology Co., Ltd
User Guide for Single Module Fiber Laser
39
NO
MESSAGE
DESCRIPTION
SOLUTION
3
IntergSamp
Laser internal optical path
detection failure
Contact our after-sales service personnel
to see if you can continue to use lasers.
4
PumpTemp
fault
The temperature of the laser
diode used as pump source
exceeds the set value.
Check whether the water cooler is
working properly; check whether the
water temperature is set correctly or not.
When the water cooler works normally
and the water temperature drops to the
set temperature, restart the laser source.
If there is any trouble, please contact our
after-sales service staff.
5
IntergHard
fault
Laser internal optical path
detection failure
Contact our after-sales service personnel
to see if you can continue to use
lasers.(
This
function is generally idle
)
6
WaterTemp
fault
The water temperature is too
high, or the water flow is below
the set value.
Check whether the water pipes are
installed correctly. Ensure the cooler is
working properly and the water flow
meets the requirements. If a fault is still
happening with everything qualified,
please contact us.
7
PrevBurn
fault
Laser internal optical path
detection failure
Contact our after-sales service personnel
to see if you can continue to use lasers.
8
CurHard
fault
The laser module supply current
exceeds
the
hardware
threshold.(Located on the main
drive circuit board )
Check if the 380V power supply of the
laser is stable. If it is stable, reduce the
peak output power of the laser. If the
fault still occurs, please contact our
after-sales service personnel.
9
IdleCur
fault
The current value when the
laser is turned off exceeds the
upper limit.
Restart the laser. If it happens frequently,
please contact our after-sales service
personnel.
10
Cooling
fault
Laser internal optical path
detection failure. Most of time,
caused by Lack of cooling.
Contact our after-sales service personnel
to see if you can continue to use lasers.
11
TrialExpi
fault
Trial time limit exceeded
Contact our after-sales service personnel
to see if you can continue to use lasers.