CAUTION
:
(1) Never make this product work in high humidity
( >
95%
)
,though the products have an excellent adaptability to
the high humidity environment.
(2)
Never let this product work below the ambient dew point
temperature(like the table 2.2)
Table 2.2 the Constant Dew Point Table
Maximum Relative
humidity (%)
20
30
40
50
60
70
80
90
95
Room
Temperature(℃)
Ambient Dew Point (Td-℃)
10
-11.9
-7
-0.3
0
2.5
4.8
6.7
8.4
9.2
15
-7.9
-2.3
1.5
4.6
7.3
9.6
11.6
13.4
14.2
20
-3.5
2
6
9
12
14.5
16.5
18
19
25
0.5
6
10.5
14
16.5
19
21
23
24
30
4.6
10.5
15
18.5
21.5
24
26
28
29
35
8.5
15
19.5
23
26
28.5
31
33
34
40
13
20
24
27.5
31
33.5
36
38
39