REC TwinPeak Series Installation Manual - UL 1703
Rev B - 03.15 

Ref: NE-06-08-B

5

panEl HanDlInG

To avoid damage to the solar cells and other components, all solar panels should be handled with care.  all warnings and instructions on the packaging 

should be observed.  Follow these guidelines when unpacking, transporting or storing the panels:

• 

Record the serial numbers prior to installation and note the information in the system documentation. 

• 

Carry the panels using both hands and avoid using the junction box as a grip.

• 

Do not allow the panels to sag or bow under their own weight when being carried. 

• 

Do not subject the panels to loads or stresses e.g., leaning or placing heavy objects on them. 

• 

Do not stand on the panels or cause impact through dropping them. 

• 

keep all electrical contacts clean and dry.

• 

Store panels in a  dry and properly ventilated room.

• 

Do not apply force to the backsheet.

• 

avoid using sharp or pointed objects if panels require marking.

• 

Never apply paints, adhesives or detergents to the back of the laminate.

• 

Do not use any solar panel that is damaged or been tampered with.

• 

Never attempt to disassemble the panels.

If the panel front glass is broken or laminate back sheet is damaged, it can expose personnel to hazardous voltages. 

MECHaNiCaL iNSTaLLaTioN 

fIRE GuIDElInEs

REC TwinPeak panels have a Class C, Type 2 Fire classification.  The fire rating of this panel is only valid when mounted in the manner specified in these 

mechanical mounting instructions.  Utilize the following fire safety guidelines when installing REC TwinPeak panels: 

• 

Check with local authorities for fire safety guidelines and requirements for any building or structure on to which the panels will be installed.

• 

The system design should ensure that it can be easily accessed in the event of a building fire.  

• 

Check with local authorities for applicable regulations concerning setbacks or other placement restrictions that may apply for roof-mounted 

arrays.

• 

The use of DC ground fault interrupters is recommended.  This may also be required by local and national codes.

• 

all electrical appliances are a fire risk.  The panel should therefore be mounted over a fire retardant roof covering rated for the application and 

a suitable distance of 4 in (100 mm) between the panel and the mounting surface, allowing free circulation of air beneath the panels, should be 

respected at all times.

oRIEntatIon

To maximize system output, panels should be installed at the optimum orientation and tilt angle.  The specifics of this depend on location and can be 

calculated by a qualified system designer.  a lower angle of panel installation increases the requirement for regular cleaning. 
The optimal mounting position of panels results in the sun’s rays falling perpendicular (i.e. at 90°) to the surface.  all panels in a string should, wherever 

possible, have the same orientation and tilt to ensure the system does not underperform due to mismatched outputs.

The panels must not be exposed to artificially concentrated sunlight.

EnVIRonmEntal faCtoRs

REC TwinPeak panels are designed to provide decades of durable and stable output.  ambient operating temperatures should be between -40 and 

185°F (-40 and +85°C). 
The panels are not suitable for installation in potentially hazardous locations nor should they be installed in the following locations: 

• 

Near sources of flammable gases or vapors

• 

Near open flames.

• 

Under water or in water features.

• 

where exposed to sulfur e.g. near sulfur springs or volcanoes.

• 

where the panels may be exposed to harmful chemicals.

Ensure panels are not exposed to direct contact with salt water/spray and avoid installation in areas subject to high salt mist content e.g. 

coastal areas.

Содержание REC265 Series

Страница 1: ...Installation manual rec TwinPeak SERIEs FortheinstallationofRECTwinPeakSeriessolarpanels certifiedaccordingtoUL1703 ...

Страница 2: ...on 4 ii Specific hazards of DC electricity 4 iv Safetyrequirements 4 MECHANICAL INSTALLATION 5 FIRE GUIDELINES 5 ORIENTATION 5 ENVIRONMENTAL FACTORS 5 Panel HANDLING 5 MOUNTING the panels 6 Panel Installation 6 i Rail specifications 6 ii Clamp Specification 6 iii Mounting holes 7 iv Slide in Systems 7 v Drainage holes 7 vi Long side mounting using clamps 8 vii Shortside mounting using clamps 8 vii...

Страница 3: ...hich highlight important information or notes Indicates potential for damage to the array or property or personal safety Indicates important notes on best practice to help with the installation or to avoid potential damage to the panels array or property For further information on installation procedures please call your distributor or contact your local REC Solar office Details available at www r...

Страница 4: ...outputs In installations not under the requirements of the NEC the values of ISC andVOC marked on the panels must be multiplied by a factor of 1 25 when determining component voltage ratings conductor ampacities overcurrent device ratings and size of controls connected to the PVoutput SAFETY Measures Wiring installation shall be in accordance with the NEC or CSA C22 1 Safety Standard for Electrica...

Страница 5: ...it can be easily accessed in the event of a building fire Check with local authorities for applicable regulations concerning setbacks or other placement restrictions that may apply for roof mounted arrays The use of DC ground fault interrupters is recommended This may also be required by local and national codes All electrical appliances are a fire risk The panel should therefore be mounted over a...

Страница 6: ...ling load Fig 2 Rail specification C channel rail H channel rail The clamps should be fastened to C or H channel rails fig 2 Thickness of walls for mechanical connections min 0 156 in 4 0 mm Thickness of walls exposed to buckling load min 0 08 in 2 0 mm Moment of Inertia for profile area about X X min array mounting diagram 0 4 in4 19 2 cm4 The overlap between support rail and the outer edge of th...

Страница 7: ...g clamps Mounting utilizing clamps on the two short sides of the panel have been found to be in compliance with UL 1703 requirements for a maximum design load of 33 4 lbs ft 1600 Pa fig 9 Fix the panels so that the lower short side of the frame is supported by the mounting structure to reduce risk of damages due to sliding snow load Clamps must be secured between a distance of 4 9 and 9 8 inches 1...

Страница 8: ...ls are preferred however galvanized or hot dipped zinc plated fasteners are equally suitable Grounding cable Star washer Grounding lug dimensions and wire fastening torque for GBL 4DBT Fig 7 Drainage holes v Drainage holes There are eight drainage holes 0 47 x 0 30 in 12 x 7 5 mm in the panels frame each spaced 2 2 in 55 mm from the corner of the panel frame fig 5 This allows water caused by rain ...

Страница 9: ...cal integrity of the cables is intact Bonding points to ground are tight secure and free from corrosion which could break the continuity between the panels and ground Recycling REC has made every effort to ensure panel packaging is kept to a minimum The paper and cardboard packaging can be recycled and the protective wrapping and panel separating blocks are also recyclable in many areas Please rec...

Страница 10: ...nder standard test conditions STC Values at STC airmass AM 1 5 irradiance 1000 W m cell temperature 25 C 77 F At low irradiance of 200 W m AM 1 5 and cell temperature 25 C at least 94 of the STC panel efficiency will be achieved followed by TP TP BLK TP ECO Fig 12 Panel dimensions in Dimensions 65 55 x 39 02 x 1 5 in Area 17 76 ft Weight 39 6 lbs Operational Temperature 40 185 F 40 85 C Maximum Sy...

Страница 11: ...10 A First release 12 2014 A 2 Update to Electrical data STC 275 Wp IMPP 12 2014 A 3 Update to Electrical data STC addition of 260 280 Wp revision of low light behavior data in Electrical Data 03 2015 B Updated to include information on panel variants ...

Страница 12: ...RECSolarPte Ltd 20TuasSouthAvenue14 Singapore637312 Singapore Tel 6564959228 Mail post recgroup com www recgroup com ...

Отзывы: