background image

 

REBOTEC / BA No.: 02.09.136/2016-12 

 

 

             GB

 

- 2 - 

Product description 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
Figure shows:

 

 

 

Main column 

Lifter arm 

Base frame 

Foot pedal with steering rod 

Swivel castor - front 

Swivel castor 

– back with locking brakes 

Swivel carrier (4 hooks) 

Bolt for carrier, ball bearing supported 

Handle with soft grips 

Drive system (motor, hoisting unit) 

Control unit 

Manual  switch 

Rechargeable battery 

Power adaptor 

Scale/PW500 

Nameplate 

 
 

Packaging 

We recommend, if possible, keeping the packaging 
for later transport. This will allow secure packaging 
in the event of a return transport. 

 
 
 
 
 

 
 

Table of Contents

 

 

1. 

General advisories 

1.1 

Introduction 

1.2 

Symbols 

1.3 

Intended use 

1.4 

Operating comfort 

1.5 

Accessories (sling and scale) 

2. 

Guarantee 

3. 

Nameplate, ordering spare parts 

4. 

Re-use, lifetime 

5. 

Disposal 

6. 

Safety instructions on use 

7. 

Product specifications 

7.1 

Delivery scope 

7.2 

Technical specifications 

8. 

Spare parts 

9. 

Setting up Patient Hoist for use 

10. 

Charging up the battery 

10.1 

Rechargeable battery 

10.2 

Hook-up and charging 

10.3 

Charge level 

11. 

Emergency OFF function 

12. 

Manual switch  

13. 

Castor brakes 

14. 

Emergency lowering  

14.1 

Electric emergency lowering 

14.2 

Mechanical emergency lowering 

14.3 

Jamming protection 

15. 

Stability, spreading the base 
frame  

16. 

Lifter arm (carrier for sling) 

17. 

Lifter arm (carrier for scale) 

18. 

Troubleshooting 

19. 

Care 

10 

20. 

Maintenance 

10 

21. 

Product spare parts  

12 

 

1. General advisories 

 

1.1  Introduction 

In this  User  Instructions  booklet  you  will  find  infor-
mation  and  advisories  for  start-up,  use,  operation, 
maintenance  and  care  of  the  Arnold  250  Patient 
Lifter. 
Read this User Instructions booklet carefully before 
using  the  product.  Pay  particularly  close  attention 
to  the  safety  instructions  and  advisories,  and  act 
accordingly.   

 

1.2 Symbols 

 

 

Read the User Instructions booklet! 

 

The product complies with the Medical 
Products Directive 93/42/EEC 

 

 

Attention! 

 

Information! 

 
 
                Warning!  Follow safety advisories 

Содержание Arnold 250

Страница 1: ...ebotec de Important advisories Read the User Instructions before first time use of the Hoist and keep it at hand for the user Store the User Instructions booklet for future use and include when resell...

Страница 2: ...ifications 4 8 Spare parts 5 9 Setting up Patient Hoist for use 5 10 Charging up the battery 6 10 1 Rechargeable battery 6 10 2 Hook up and charging 7 10 3 Charge level 7 11 Emergency OFF function 7 1...

Страница 3: ...ly REBOTEC accessories as only these can assure a trouble free and safe function 2 Warranty There is a 2 year warranty on the product A pre requisite for the warranty are the general terms and conditi...

Страница 4: ...tient swinging must be avoided because of an increased risk of an accident Never leave the patient unsupervised when us ing the Patient Hoist An unforeseen movement or action by the patient may lead t...

Страница 5: ...he wheel castors see page 8 section 13 so that the hoist unit cannot roll away Step 2 Install the control unit Insert the hooks 1 of the control unit K in the hole of the main column Next lay the cont...

Страница 6: ...drive motor to the lifting axis remove the safety ring 1 and the pin 2 from the borehole of the lifting arm B Next raise the lifter arm B and align the borehole of the lifting axis with the lifter ar...

Страница 7: ...as 20 hours If the charging process lasts longer than 21 hours then the rechargeable battery or the charging unit is defective When the rechargeable battery is charged up first unplug the charging uni...

Страница 8: ...sible but then the rechargeable battery must be recharged 14 2 Mechanical emergency lowering In the event the patient becomes exposed to an emergency situation or an electrical defect occurs with the...

Страница 9: ...atient Hoist with scale If the Patient Hoist is equipped with a PW 500 scale then also use the additional User Instruc tions for the scale User Instructions No 02 09 107 This User Instructions booklet...

Страница 10: ...ge the plastic surfaces or cause deposits to build up on the plastic parts and other materials Emergency lowering The emergency lowering mechanism may not be treated with oil grease or other lubricant...

Страница 11: ...versely affect the safety and function of the Hoist In such cases the manufacturer RE BOTEC overtakes no liability Follow all the instructions when ordering spare parts re use and product lifetime of...

Страница 12: ...4 Power supply adaptor Type M 100 240V 0 8 0 4 A 50 60 Hz 6 422 51 25 Swivel castor 125 mm 2 7 422 51 50 Swivel castor with locking brake 150 mm 2 8 420 00 15 Rubber cap for pedal 2 9 420 00 12 Foot p...

Отзывы: