background image

 

REBOTEC / BA No.: 02.09.136/2016-12 

 

 

             GB

 

- 12 - 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

21. Spare parts: Arnold 250/250+Scale 

No. 

Art. No. 

Name 

Qty. 

1  433.00.71  Linear drive, Type A/(7A) 

2  433.10.72  Control unit, Type A/(24VDC / 9A) 

3  433.10.70  Rechargeable battery, Type A/ (24VDC / 4.5Ah)  

4  433.10.75  Manual switch, Type A/ (24VDC)  

5a  420.00.74  Power supply adaptor Type A/ (230 V / 0,5 A / 50 Hz) 

5b  420.30.74  Power supply adaptor Type M/ (100-240V / 0.8-0.4 A / 50-60 Hz) 

6  422.51.25  Swivel castor (Ø 125 mm)  

7  422.51.50  Swivel castor with locking brake (Ø 150 mm)  

8  420.00.15  Rubber cap for pedal 

9  420.00.12  Foot pedal 

10  420.25.83  Angle connector rod complete. (L=250 mm) 

11  420.95.22  Handle for main column 

12a  433.00.43  Bolt D30x155 mm  

12b  860.60.02  Ball bearing for bolt D30  

13  433.00.42  Carrier 250 complete. 

14  433.00.46  Velcro padding for carrier 250  

15  420.05.01  Scale PW 500 with bow (calibrated) 

 

11 

13 

10 

14 

12a/b 

15 

Содержание Arnold 250

Страница 1: ...ebotec de Important advisories Read the User Instructions before first time use of the Hoist and keep it at hand for the user Store the User Instructions booklet for future use and include when resell...

Страница 2: ...ifications 4 8 Spare parts 5 9 Setting up Patient Hoist for use 5 10 Charging up the battery 6 10 1 Rechargeable battery 6 10 2 Hook up and charging 7 10 3 Charge level 7 11 Emergency OFF function 7 1...

Страница 3: ...ly REBOTEC accessories as only these can assure a trouble free and safe function 2 Warranty There is a 2 year warranty on the product A pre requisite for the warranty are the general terms and conditi...

Страница 4: ...tient swinging must be avoided because of an increased risk of an accident Never leave the patient unsupervised when us ing the Patient Hoist An unforeseen movement or action by the patient may lead t...

Страница 5: ...he wheel castors see page 8 section 13 so that the hoist unit cannot roll away Step 2 Install the control unit Insert the hooks 1 of the control unit K in the hole of the main column Next lay the cont...

Страница 6: ...drive motor to the lifting axis remove the safety ring 1 and the pin 2 from the borehole of the lifting arm B Next raise the lifter arm B and align the borehole of the lifting axis with the lifter ar...

Страница 7: ...as 20 hours If the charging process lasts longer than 21 hours then the rechargeable battery or the charging unit is defective When the rechargeable battery is charged up first unplug the charging uni...

Страница 8: ...sible but then the rechargeable battery must be recharged 14 2 Mechanical emergency lowering In the event the patient becomes exposed to an emergency situation or an electrical defect occurs with the...

Страница 9: ...atient Hoist with scale If the Patient Hoist is equipped with a PW 500 scale then also use the additional User Instruc tions for the scale User Instructions No 02 09 107 This User Instructions booklet...

Страница 10: ...ge the plastic surfaces or cause deposits to build up on the plastic parts and other materials Emergency lowering The emergency lowering mechanism may not be treated with oil grease or other lubricant...

Страница 11: ...versely affect the safety and function of the Hoist In such cases the manufacturer RE BOTEC overtakes no liability Follow all the instructions when ordering spare parts re use and product lifetime of...

Страница 12: ...4 Power supply adaptor Type M 100 240V 0 8 0 4 A 50 60 Hz 6 422 51 25 Swivel castor 125 mm 2 7 422 51 50 Swivel castor with locking brake 150 mm 2 8 420 00 15 Rubber cap for pedal 2 9 420 00 12 Foot p...

Отзывы: