background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Manufacturing dimensional tolerances:  +/- 2 cm 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

BA No.: 02.09.136/2016-12 

Patient Hoist 

– Arnold 250/250+Scale

 

 

 

 

                    

 

   

 

 

 

 

 
 
 

User Instructions 

GB 

REBOTEC

®

  

 

Rehabilitationsmittel GmbH 

DE-49610 Quakenbrück, Artlandstr. 57-59 
Tel: +49(0)5431/9416-0 
Fax: +49(0)5431/9416-66 

http://www.rebotec.de 

E-mail: [email protected] 

 

Important advisories! 

  Read the User Instructions 

before first time use

 of the Hoist and keep it at hand for the user. 

  Store the User Instructions booklet for future use, and include when reselling the unit. 

  The user instructions and the maintenance manual are downloadable on our homepage. 

 

 

Dimensions/cm 

Max. carry load 

250 kg 

Art. No.: 330.05.00 

Serial Number 

 
 
             
 

 

 

 

 

 

 

06/2005 (Th.B.) 

Arnold 250+Scale 

Art. No.: 330.00 

Serial Number 

 
 
             
 

 

 

 

 

 

 

06/2005 (Th.B.) 

Arnold 250 

98 

70 

48 

130 

177 

18 

(31) 

(164) 

Содержание Arnold 250

Страница 1: ...ebotec de Important advisories Read the User Instructions before first time use of the Hoist and keep it at hand for the user Store the User Instructions booklet for future use and include when resell...

Страница 2: ...ifications 4 8 Spare parts 5 9 Setting up Patient Hoist for use 5 10 Charging up the battery 6 10 1 Rechargeable battery 6 10 2 Hook up and charging 7 10 3 Charge level 7 11 Emergency OFF function 7 1...

Страница 3: ...ly REBOTEC accessories as only these can assure a trouble free and safe function 2 Warranty There is a 2 year warranty on the product A pre requisite for the warranty are the general terms and conditi...

Страница 4: ...tient swinging must be avoided because of an increased risk of an accident Never leave the patient unsupervised when us ing the Patient Hoist An unforeseen movement or action by the patient may lead t...

Страница 5: ...he wheel castors see page 8 section 13 so that the hoist unit cannot roll away Step 2 Install the control unit Insert the hooks 1 of the control unit K in the hole of the main column Next lay the cont...

Страница 6: ...drive motor to the lifting axis remove the safety ring 1 and the pin 2 from the borehole of the lifting arm B Next raise the lifter arm B and align the borehole of the lifting axis with the lifter ar...

Страница 7: ...as 20 hours If the charging process lasts longer than 21 hours then the rechargeable battery or the charging unit is defective When the rechargeable battery is charged up first unplug the charging uni...

Страница 8: ...sible but then the rechargeable battery must be recharged 14 2 Mechanical emergency lowering In the event the patient becomes exposed to an emergency situation or an electrical defect occurs with the...

Страница 9: ...atient Hoist with scale If the Patient Hoist is equipped with a PW 500 scale then also use the additional User Instruc tions for the scale User Instructions No 02 09 107 This User Instructions booklet...

Страница 10: ...ge the plastic surfaces or cause deposits to build up on the plastic parts and other materials Emergency lowering The emergency lowering mechanism may not be treated with oil grease or other lubricant...

Страница 11: ...versely affect the safety and function of the Hoist In such cases the manufacturer RE BOTEC overtakes no liability Follow all the instructions when ordering spare parts re use and product lifetime of...

Страница 12: ...4 Power supply adaptor Type M 100 240V 0 8 0 4 A 50 60 Hz 6 422 51 25 Swivel castor 125 mm 2 7 422 51 50 Swivel castor with locking brake 150 mm 2 8 420 00 15 Rubber cap for pedal 2 9 420 00 12 Foot p...

Отзывы: