Setup with internal inline fan module with
roof top termination – mid flue mounted
Maximum 5m flue length
Roof top termination
1. Rooftop termination must be installed with clearances
as specified by AS5601.1-2013.
2. Run exhaust flue and air intake flue as required –
Maximum total run 5m per flue. Flues can be run next
to each other. Maintain clearances to combustibles.
3. Mount fan controller in the required location. (Access
to the fan module is required for servicing, if the fan
module is located inside a boxed frame, allow a 450
x 450 access panel).
NOTE –
a minimum of 2m of flue must be run between
appliance and fan module.
Run flue from appliance
to bottom entry on fan
module.
NOTE: A minimum of
2m of flue must be run
between appliance and
fan module.
Support flue with brackets
as required
Cut flue to length to suit
connection.
Ensure ends are burr free
and round, test fit flue will
fit over connection.
Apply an 8mm silicon
bead fully around the
inside of the flue end
(heater connection end)
Fit flue clamp over flue
(loosely).
Apply an 8mm thick silicon
bead fully around heater
connection approx. 10mm
from the top.
Slide flue onto connection
spigot fully.
Tighten clamp fully.
Wipe excess silicon,
visually check connection
to ensure connection is
fully sealed