Feed hot exhaust flue
into connection, ensure
inserted 50mm. Fit retaining
screw from below.
Locate terminal on wall and predrill mounting holes where
required.
Cut flue exhaust tube (hot tube) to length (Flue must
extend a minimum of 50mm past the exit face of wall.) It
is recommended that the tubes are cut slightly longer and
pushed back into wall upon fixing of wall terminal. Allow
flue movement between terminal and last flue hanging
clip.
Cut Air intake as per flue exhaust.
Ensure ends are burr free and round, test fit flue will slide
inside both the hot exhaust connection and air intake
connection.
Feed air intake flue
into connection, ensure
inserted 50mm. Fit retaining
screw from below.