T R O U B L E S H O O T I N G F O R YO U R F I R E P L A C E
Problem
Possible Cause
Suggested Solution
When the remote is activated nothing
happens
1200 models - gas supply is turned
off or low pressure Powerflue fan
loom is not connected Flues not
connecte or incorrectly installed;
refer red/black labels
Reprogram the remote to the receiver
(Refer to the Remote section in the
manual)
The remote batteries are flat
Replace the Battery
The remote operates but appliance
does not operate or spark
1200 models - gas supply is turned
off or low pressure
Check if the gas supply is turned on
and the pressure is optimum
Powerflue fan loom is not connected Connect Powerflue fan loom
Flues not connected or incorrectly
installed; refer red/black labels
Check Installation and connect flues
The fire cuts off and won’t relight
The over temp snap disc has been
activated.
Allow the fire to cool down and then
try to relight the fire. If the fire fails to
relight, contact the manufacturer.
The fan will not come on
Possible caused by overheat or
electrical fault.
Contact the manufacturer.
Flame appears to be low
Pressure not set
All pressures are set in the factory at
the time of manufacture, however the
installing plumber mus make sure the
pressures are correct.
*If your fireplace still does not operate correctly consult your dealer. All service and repairs should be performed by
an authorised agency. All spare parts and optional trim finishes are available from glen dimplex pty ltd.