-18-
Burner Media Installation
Logs/Coals and Vermiculite
•
Fit the Rear Log Locator panel (supplied with the Logs and Coals) to the back of the burner using 4
screws.
•
Use a flat screw driver or similar to bend all of the log locating tags up wards until square to the burner.
•
Place (DO NOT POUR*) all of the supplied vermiculite on the burner and spread evenly across the
entire surface of the burner.
•
Place one coal onto each of the 23 Locating Pins. The coals are to be located centrally and at the same
angle as the tag. Push the coals down until they are just sitting on the bed of vermiculite.
•
Place the remaining coals (a total of 27 should be used to get maximum efficiency) and the supplied
twigs over the first row of coals.
•
Once all the logs and coals are in place, light the fire and assess the look of the flames. If there are any
areas that have very long streaky flames then, using a pair of tongs, move the top logs or coals to
another position until the flames are more even across the whole burner.
Pebbles / Crystals (crushed glass)
Place (DO NOT POUR*) all of the supplied Pebbles or Crystals evenly across the entire area of the burner. The
finished depth will be about 2~3 pebbles or about 20 mm of Crystals.
Do not pile glass or pebbles over the top of the pilot assembly as this could affect it performance. It may be
possible to build the media up around the pilot to hide it slightly but always check that the pilot is operating at its
optimum when finished.
(Refer to Pilot Burner Performance page 13)
*Pouring the media over the burner can block the burner ports with the fine dust that tends to settle in the bottom of the bags during shipping
*Pouring the
media over the
burner can block
the burner ports
with the fine dust
that tends to settle
in the bottom of
the bags during
shipping