Page 33
Programming Menu
Real Carriage Door & Sliding Hardware Copyright 2020© all rights reserved
Main
Selec-
tion
Descrip-
tion
De-
fault
Range
LOGIC> HOLD-
TO-RUN
Requires
continuous
OPEN or
CLOSE
command
input for
gate to
operate.
0=OFF /
1=ON
0
0-2
LOGIC>
IBL
OPEN
Ignores
START in
-
put during
the open-
ing cycle
0
0-1
LOGIC>
IBL TCA Ignores
the START
input while
counting
down for
automatic
closing
0=OFF /
1=ON
0
0-1
LOGIC>
IBL
CLOSE
Ignores the
START in
-
put during
the clos-
ing cycle.
O=OFF /
1=ON
0
0-1
LOGIC>
RAM
BLOW C.
OP
Push
-
es gate
against
physical
stop before
opening
0
0-1
LOGIC>
RAM
BLOW C.
CL
Push
-
es gate
against
physical
stop before
closing
0
0-1
LOGIC> BLOC
PERSIST
Hourly
push
against
physical
stop
0
0-1
Main
Selec-
tion
Descrip-
tion
De-
fault
Range
LOGIC>
PRESS
SWC
Push
-
es gate
against
physical
stop for .5
seconds
after close
limit has
been react-
ed
0
0-1
LOGIC>
ICE
Continu-
ous force
learning
on every
operation
0
0-1
LOGIC> OPEN IN
OTHER
DIRECT.
0 - Pull to
open / 1=
Push to
open
0
0-1
LOGIC>
SAFE 1 *
Configu
-
ration of
safety input
terminal
72. Default
-
ed as Phot
Test (Ob
-
struction)
1
1 & 5
LOGIC>
SAFE 2 *
Configu
-
ration of
safety input
terminal
74. Default
-
ed as BAR
(Safety
Edge)
6
0-15
LOGIC>
SAFE 3 *
Config
-
uration
of safety
input ter-
minal 75.
Defaulted
as SHAD-
OW (Safety
Loop)
15
0-15
Содержание Franklin Autoswing