Page 32
Programming Menu
Real Carriage Door & Sliding Hardware Copyright 2020© all rights reserved
Main
Selec-
tion
Descrip-
tion
De-
fault
Range
PARAM> OP.
FORCE
Percentage
of opening
force exert-
ed over the
AUTOSET
value
before
obstruction
is sensed
50
1-99
PARAM>
CLS.
FORCE
Percentage
of closing
force exert-
ed over the
AUTOSET
value
before
obstruction
is sensed
50
1-99
PARAM> OP
SPEED
Motor
opening
speed
expressed
in percent-
age
99
15-99
PARAM>
CL
SPEED
Motor clos
-
ing speed
expressed
in percent-
age
99
15-99
PARAM> SLOW
SPEED
Slowdown
speed
expressed
in percent-
age from
maximum
speed
25
15-99
LOGIC> MOTOR
TYPE
1=Eli 250;
2=Phobos
BT
3=
Igea
BT
0
LOGIC>
TCA
Timer to
Close Auto-
matically.
0=OFF /
1=ON
0
0-1
Main
Selec-
tion
Descrip-
tion
De-
fault
Range
LOGIC>
FAS T
CLS.
Closes
when
sensors
are cleared.
0=OFF /
1=ON
0
0-1
LOGIC> STEP-
BY-STEP
MOVE
-
MENT
Determines
how the
system re-
acts when
a START
command
is received
during
operation
0
0-2
LOGIC>
SHAD-
OW
Config
-
uration
of safety
loop input
terminal 74
or 77 when
SAFE 2 or
SAFE 3 are
set as 015
(SHADOW)
0
0-1
LOGIC>
SAFE 3*
Config
-
uration
of safety
input ter-
minal 76.
Defaulted
as SHAD-
OW (Safety
loop)
15
0-15
LOGIC> PRE-
ALARM
Gate run
-
ning output
(AUX val
-
ue=6) clos
-
es 3 sec.
before gate
movement
0=OFF /
1=ON
0
0-1
Содержание Franklin Autoswing