12. When Parameter "H" is displayed and accepted, depress "GO" to accept and proceed to
Parameter "I".
• If Parameter "H" needs to be modified, depress "CAL" and modify the value to
produce desired stop point. Select "GO" to accept.
• Empty Scale pan
• Enter charge weight
• Depress "GO" to dispense
• Unit will again step through all previous Parameters. Follow process above to accept
or modify parameters.
13. If Parameter "H" has been accepted and "GO" is depressed, the Short Trickle operation,
parameter "I" will begin and trickle until the desired target dispense charge is reached.
• Display will flash between weight and parameter "I".
• If "I" is acceptable depress "GO" to accept and complete Step Process.
• If parameter "I" needs to be changed depress the "CAL" button. Parameter "I" will
display. Change the value and select "GO" to accept.
• Test will appear on the display, depress "GO" to continue test
• Empty Scale pan
• Enter charge weight
• Depress "GO" to dispense
• Unit will step through all Parameters, depress "GO" to accept if parameters produce
desired results. If not, depress "CAL" to modify any of the values.
14. When step process reaches Parameter "I" and all values have been accepted, depress "GO"
to exit out of Step Function. Empty scale pan, enter desired charge weight and begin
dispensing using your new User defined Powder Dispense Parameters.