5.2.2 Power sensor
Connect the Power sensor COM cable to the Main board at the correct connector location by
following writings on the Main board. Be careful if you have a dual main board make sure
your cables are connected on the correct side (A or B side).
5.2.3 Temperature probe
Connect the Temperature probe COM cable to the Main board at the correct connector
location by following writings on the Main board. Please use the thermal adhesive to glue
the temperature sensor on the devices that you need to measure the temperature. There are
additional instructions built-in to the software. Please contact our technical team for more
information.
5.2.4 Air-speed probe
The Series 1780 can be connected to one pressure probe (additional purchase required) for
connecting to a wind tunnel Pitot tube. You should connect the pressure probe on the
“Addons” port of the main board. After the probe is detected by the software, additional
instructions will be available in the software.
5.3 Control chain
5.3.1 Power and control console
Connect the control COM cable to the Main board at the correct connector location by
following writings on the Main board. Be careful if you have a dual main board, make sure
your cables are connected on the right side (A or B side).
Then connect your ESC’s control cable (small 3-pin connector) to the connectors available on
the Power and control console. Make sure to use the correct polarity, and follow the pin
assignment as printed on the casing.
Copyright 2019 - Tyto Robotics Inc.