Range:
1 to 9
Default:
5 (Displacement)
5 (Semi-displacement)
4 (Planing)
3 (Sterndrive)
Rate level
Rate Level applies rudder to reduce rate or changes of course. Rate
level will, if the rate at which the vessel is turning is too fast, counter this
turn with opposite rudder.
The settings available are as follows:
Range:
1 to 9
Defaults:
7
Displacement
7
Semi-displacement
7
Planing
5
Sterndrive
Rudder offset
You only need to set this option if your system includes a rudder
reference unit.
• Manually place the helm in a central position. The reported rudder
angle is indicated on the rudder bar graphic at the bottom of the
screen.
• Adjust the offset value, using the
+1
and
-1
keys, until the rudder
position is shown as central on the rudder bar. The offset must be
within the range -7° to +7°.
Range:
–7° to +7°
Default:
0
Rudder limit
Rudder Limit restricts autopilot rudder movement to just less than the
steering system’s mechanical stops. This avoids putting the steering
system under unnecessary load.
133_3c04.p65
14/06/99, 10:23
36
Содержание ST6000 Plus
Страница 2: ...133_3cov p65 14 06 99 10 23 2 ...
Страница 4: ...ii ST6000PlusAutopilotControlUnitOwner sHandbook 133_3pre p65 14 06 99 10 23 2 ...
Страница 10: ...viii ST6000PlusAutopilotControlUnitOwner sHandbook 133_3pre p65 14 06 99 10 23 8 ...
Страница 40: ...28 ST6000PlusAutopilotControlUnitOwner sHandbook 133_3c03 p65 14 06 99 10 23 28 ...
Страница 56: ...44 ST6000PlusAutopilotControlUnitOwner sHandbook 133_3c04 p65 14 06 99 10 24 44 ...
Страница 76: ...64 ST6000PlusAutopilotControlUnitOwner sHandbook 133_3c07 p65 14 06 99 10 24 64 ...
Страница 86: ...133_3tem p65 14 06 99 10 24 2 ...
Страница 88: ...133_3tem p65 14 06 99 10 24 4 ...