www.rayteccctv.com
19
Raytec Global Tel: +44 (0) 1670 520055
Raytec Americas Tel: +1 613 270 9990
WARNING: For changes to take effect, the SAVE button must be pressed
WARNING: You cannot see the effect of your changes if the override button on the
Home Page is still active (green) or your lamp is in group override control from
another lamp
Local (No VMS server)
For the lamp to operate from the integrated web interface
– this tick box must be selected. If
the lamp is to be operated from a VSM or other control system, then this tick box must NOT
be selected.
Group Name
A lamp can be associated with a new or existing group to enable it to follow group
commands from the photocell input and/or External Input. A new group name can be created
by typing into the <Enter Group Name> box. Ensure that duplicate names are avoided. Or
the lamp can be allocated to an existing group by selecting an existing group from the drop
down list of groups.
Trigger Control
For both Photocell and External Input, the user can select 3 action states:
1. Inactive
the lamp ignores the input
2. Lamp Control
the lamp will respond to its own input
3. Group Control
the lamp will respond to an input from lamps within its named
Group
– based on selection from Respond to Group Commands
below
Factory Defaults:
Photocell
Lamp Control
External Input
Lamp Control
Respond to Group Commands
If Group control is NOT selected from Trigger Control options, then the lamp will not respond
to any Group commands.
If Group Control is selected from Trigger Control options, then the user can select two
modes of operation in response to Group Commands: