Surface/Ceiling Mount Installation (Ordered Separately)
Step 1.
Step 2.
Step 3.
Step 4.
Warning
!
!
Warning
(Brackets are ordered separately)
Refer to alternate instructions if using Conduit, Hook, Wall, Pole or Yoke Mount
Inspect shipping package and contents to ensure no
damage has occurred during shipping.
Remove 8x M6 hex cap bracket mounting screws from
head and re-install with included Surface/Suspension
Mount Brackets. See diagram for orientation of brackets.
Torque M6 bolts to 5 Nm (45 in-lbs).
A) For surface mounting configuration, mount luminaire
in desired ceiling location using 4x 1/4-20 OR 4x M6
fasteners and washers (Not provided). One mounting hole
on each bracket is keyed to allow partial pre-installation of
two fasteners for ease of install.
Open AR Lens with a 7mm socket or wrench and allow
Lens to hang via retention strap.
Note: Screws are captive fasteners and will remain
attached to the Lens for ease of reinstall and to prevent
loss of fasteners.
B) For ceiling mounting configurations, connect 4x
anchors to the 12.7mm (0.5”) holes.Suspension hardware
(Not provided) must be rated for a minimum of 180 lbs.
Step 2
Step 3A
Step 3B
To avoid the risk of fire, explosion, or electric shock, this
product should be installed, inspected, and maintained
by a qualified electrician only, in accordance with all
applicable electrical codes.
To reduce the risk of electric shock, disconnect the luminaire
from the supply circuit before opening for installation and
servicing. Keep tightly closed when in operation.
5.0in
126mm
5.2in
132mm
21.1in
535mm
22.5in
570mm
0.5in
12.7mm
0.3in
6.8mm
0.5in
12.7mm
0.5in
12.7mm
0.5in
12.7mm
0.5in
12.7mm
SPI-AR