IM-182
HOLOPHANE
HOLOPHANE
HOLOPHANE
HOLOPHANE
MILWAUKEE LANTERN
Installation and
Maintenance
Manual
AFTER INSTALLATION DELIVER THIS
MANUAL TO OWNER
IMPORTANT SAFETY INSTRUCTIONS
WARNING
–
READ THESE INSTRUCTIONS
CAREFULLY BEFORE ATTEMPTING TO INSTALL OR
MAINTAIN THIS FIXTURE. WORK MUST BE DONE BY
QUALIFIED PERSONNEL.
WARNING
–
BE CERTAIN THAT ALL ELECTRICAL
POWER IS DISCONNECTED
FROM THE FIXTURE BEFORE INSTALLING
OR MAINTAINING THE FIXTURE.
WARNING
–
FOLLOW LAMP MANUFACTURER’S
OPERATING AND MAINTENANCE INSTRUCTIONS.
FAILURE TO FOLLOW THESE WARNINGS
MAY RESULT IN DEATH, INJURY OR SIGNIFICANT
PROPERTY DAMAGE.
GR2008
1. INTRODUCTION
1.1 Product Description.
•
The Milwaukee Lantern Luminaire has been designed to
distribute specific patterns of light on the surface below. All
optics have street side orientation on the flange of the refractor.
•
The Milwaukee Lantern luminaire is designed for easy
maintenance.
•
The lamp can easily be replaced by loosening a screw and
swinging down the refractor door.
•
Electrical components are mounted on an easily accessible
ballast assembly door.
1.2 Alternate Information Sources.
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
(866) 759-1577
2. INSTALLATION
2.1 Tools and Material Required.
Table 1. Installation Tools and Materials
DESCRIPTION
USE
1/8” Hex wrench
Set screws (mounting, optical assy.)
3/8" nut driver or medium ballast mounting screws, reflector screws,
flat blade screw driver
ballast door screw
Torque wrench
Set screws
Pipe Thread Sealant
mounting pipe threads
¾” Socket wrench
Luminaire mounting screws
Figure 1
GR2003
2.2 Luminaire Installation.
2.2.1
Feed supply leads from pole through wireway hole.
2.2.2
Attach optical assembly to Arm assembly. Apply pipe thread
sealant to the first 4 male threads on the mounting pendant, make
sure to apply completely around the threaded pendant. Force the
sealant into the threads using a finger or similar tool. See Figure 2.
Thread the mounting assembly onto the pipe threads. Tighten by
hand until the threads begin to feel tight. Tighten at least one
additional full rotation and orient the reflector door screw toward the
street. Refractor is marked "street side." Tighten set screws at
threaded entry hole to 10-12 foot pounds.