background image

 

 

IM-182 

HOLOPHANE

HOLOPHANE

HOLOPHANE

HOLOPHANE

 

MILWAUKEE LANTERN 

Installation and 

 

 

Maintenance 

 

 

Manual 

AFTER INSTALLATION DELIVER THIS 

MANUAL TO OWNER 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

WARNING 

– 

READ THESE INSTRUCTIONS 

CAREFULLY BEFORE ATTEMPTING TO INSTALL OR 
MAINTAIN THIS FIXTURE.  WORK MUST BE DONE BY 
QUALIFIED PERSONNEL. 

WARNING

 – 

BE CERTAIN THAT ALL ELECTRICAL 

POWER IS DISCONNECTED  
FROM THE FIXTURE BEFORE INSTALLING  
OR MAINTAINING THE FIXTURE. 

WARNING

 – 

FOLLOW LAMP MANUFACTURER’S 

OPERATING AND MAINTENANCE INSTRUCTIONS. 
 

FAILURE TO FOLLOW THESE WARNINGS  

MAY RESULT IN DEATH, INJURY OR SIGNIFICANT 

PROPERTY DAMAGE. 

 
 

 

GR2008 

 

1.  INTRODUCTION 
 
1.1  Product Description.  

 

 

The Milwaukee Lantern Luminaire has been designed to 
distribute specific patterns of light on the surface below. All 
optics have street side orientation on the flange of the refractor. 

 

The Milwaukee Lantern luminaire is designed for easy 
maintenance. 

 

The lamp can easily be replaced by loosening a screw and 
swinging down the refractor door. 

 

Electrical components are mounted on an easily accessible 
ballast assembly door. 

 

1.2 Alternate Information Sources. 

  

 

Holophane 

Field Service Department 

P.O. Box 3004 

Newark, OH  43058-3004 

(866) 759-1577 

 
2. INSTALLATION 

 

2.1 Tools and Material Required. 

 

Table 1.  Installation Tools and Materials

 

DESCRIPTION 

USE 

1/8” Hex wrench 

Set screws (mounting, optical assy.) 

3/8" nut driver or medium  ballast mounting screws, reflector screws, 
flat blade screw driver 

ballast door screw 

Torque wrench 

Set screws  

Pipe Thread Sealant 

mounting pipe threads 

¾” Socket wrench 

Luminaire mounting screws  

 
Figure 1 

 

 

GR2003 

 
2.2 Luminaire Installation. 

 

2.2.1 

Feed supply leads from pole through wireway hole. 

2.2.2

 Attach optical assembly to Arm assembly.  Apply pipe thread 

sealant to the first 4 male threads on the mounting pendant, make 
sure to apply completely around the threaded pendant.  Force the 
sealant into the threads using a finger or similar tool.  See Figure 2.  
Thread the mounting assembly onto the pipe threads.  Tighten by 
hand until the threads begin to feel tight.  Tighten at least one 
additional full rotation and orient the reflector door screw toward the 
street.  Refractor is marked "street side." Tighten set screws at 
threaded entry hole to 10-12 foot pounds. 

Отзывы: