background image

Raytec Americas: 

+1 613 270 9990 • [email protected]

Raytec Ltd reserve the right to change specifications without prior notification or public announcement.

Version 1

www.raytecled.com

1277-D

-0002

Installation Steps

Secondary Safety Kit (Ordered Separately)

Step 1.

Step 2.

Step 3.

Step 4.

This SPX-BKT-AR-SK-## kit is intended for use with UL Listed AR luminaire as marked on the luminaire nameplate.

Accessory Package Contents

Remove the bottom-left pre-installed M6 x 16mm Hex Cap Screw.

Install bracket on AR luminaire as shown using supplied M6 x 20mm Hex Cap Screw. 
Torque M6 x 20mm Hex Cap Screw to 40 in-lbs (4.5 Nm). It is strongly recommended 
that a medium or high strength thread-locker be used when installing the bracket. For 
units using surface or suspension mounting, install safety kit hardware on top of the 
surface mount or suspension mount brackets in the same location as shown.

- Attach loose end of stainless steel chain to fixed eye-bolt (not supplied) using 
the second stainless steel oval shaped threaded connecting link.

- Alternate attachment method: Wrap loose end of chain around fixed beam or 
other immovable support and create a closed loop using the second stainless 
steel oval shaped threaded connecting link. Supporting beam or structure must 
form a closed loop to prevent the secondary safety chain from slipping off or 
becoming unhooked.

Attach  stainless  steel  chain  to  safety  kit  bracket  using  stainless  steel  oval 
shaped threaded connecting link.

Attach loose end of chain. Secondary safety mounting point must be suitable for 
supporting a minimum of 120lbs:

SPX-BKT-AR-SK-##

QTY

PART NAME

1

1003-01-02-301 (ZLM Secondary Safety)

1

M6 Flat Washer

1

M6 x 20mm Hex Cap Screw

2

Oval Shaped Threaded Connecting Link

1

Stainless Steel Chain, 1/8” Trade Size

Step 1

Step 2

SPI-AR

M6 SCREW

1

2

3

Содержание AR10

Страница 1: ... minimum of 90 C Class 1 Wiring only Dimming control wires must be rated 300V minimum for luminaires with suffix AC 600V minimum for luminaires with suffix HV Certified to Connections Housing Ingress Protection Temperature Range Input Voltage Electrical Ratings Copper free Cast Aluminium with Polycarbonate lens IP66 67 Suitable For Wet Locations Marine Outside Type Salt Water Based on luminaire su...

Страница 2: ...rs Not provided One mounting hole on each bracket is keyed to allow partial pre installation of two fasteners for ease of install Open AR Lens with a 7mm socket or wrench and allow Lens to hang via retention strap Note Screws are captive fasteners and will remain attached to the Lens for ease of reinstall and to prevent loss of fasteners B For ceiling mounting configurations connect 4x anchors to ...

Страница 3: ...can be wired as Class 1 or Class 2 Circuit LED Drivers will source a combined maximum of 400µA for control needs 0 10V Controller must sink current from LED driver 0 10V control connections NOTE To aid in assembly and protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integ...

Страница 4: ... reserve the right to change specifications without prior notification or public announcement Version 1 www raytecled com 1277 D 0002 SPI AR PS 1 PS 2 GROUND Factory WHITE GREEN PURPLE GREY Wiring Diagram Black Line White Neutral Green Ground Purple DIM Grey DIM BLACK ...

Страница 5: ...bracket provided with AR luminaire Remove 4 x M6 bolts from supply side of luminaire and disard Install the provided plastic 3 4 bushing into side 3 4 NPT entry Insert and tension M6 set screw to pole to lock rotation Resume installation instructions provided with luminaire STEP 4 in AR Installation Instructions provided with Luminaire Install Pole Mount and gasket with adhesive side applied to mo...

Страница 6: ... petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrity of the enclosure Install Back Cover Plate with 4x M4 Flat head screws and adhesive backed gasket Apply gasket with adhesive side applied to mount main body Torque to 1 7 N m 15 in lbs Mount luminaire assembly to desired location using 4x 1 4 20 OR ...

Страница 7: ... assembly and protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrity of the enclosure Mount luminaire assembly to desired location using 4x 1 4 20 OR M6 Screws or Bolts Not Provided Adjust and aim luminaire to desired position Torque hardware nuts to 9 N m 80 in lbs R...

Страница 8: ...stening a closed loop Secondary safety hardware must be rated for a minimum of 180lbs Secondary safety cables made from stainless steel aircraft cable are available upon request Install remaining loop of secondary safety chain or steel cable to suitable mounting location and fasten securely Resume installation instructions provided with luminaire STEP 4 in AR Installation Instructions provided wit...

Страница 9: ...nipple Tighten to hand tight contact plus 1 to 2 turns Slide anti rotation lock into place and tighten set screw to lock unit in place Fixed Rigid Metal Conduit must be suitably mounted to prevent rotation and system must be rated for 180 lbs NOTE To aid in assembly and protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used ...

Страница 10: ...ration yoke mount arms Rotate luminaire to aim in the desired direction and fasten in place using 2x M6 socket head cap screws and flat washers per side Torque fasteners to 5 Nm 45 in lbs Resume installation instructions provided with luminaire STEP 4 in AR Installation Instructions provided with Luminaire WARNING The AR Head must not face upwards by any degree beyond the vertical position for Cla...

Страница 11: ...ll remain attached to the Lens for ease of reinstall and prevent loss of fasteners Close AR lens Ensure the retention cable is not pinched between AR Head and the AR Lens Tighten lens bolts using a 7mm socket or box wrench to 1 7 N m 15 in lbs in the order designated in the diagram to ensure gasket sealing Install provided double sided tape along side of surge protector Remove backing paper and pl...

Страница 12: ... 1 Disconnect Line Input branch circuit conductor from splice or terminal connected to Black leads from LED Driver Re connect Line Input branch circuit conductor to Black wire from surge protector 2 Connect Orange Black wire from surge protector to splice or terminal connected to Black leads from LED Drivers 3 Connect White lead from surge protector to splice or terminal connected to Neutral Input...

Страница 13: ...ll remain attached to the Lens for ease of reinstall and prevent loss of fasteners Close AR lens Ensure the retention cable is not pinched between AR Head and the AR Lens Tighten lens bolts using a 7mm socket or box wrench to 1 7 N m 15 in lbs in the order designated in the diagram to ensure gasket sealing Install provided double sided tape along side of surge protector Remove backing paper and pl...

Страница 14: ...nnected to Black leads from LED Driver Re connect Line Input branch circuit conductor to Orange wire from surge protector 2 Connect Orange Black wire from surge protector to splice or terminal connected to Black leads from LED Drivers 3 Disconnect Neutral Input branch circuit conductor from splice or terminal connected to White leads from LED Driver Re connect Neutral Input branch circuit conducto...

Страница 15: ...e on top of the surface mount or suspension mount brackets in the same location as shown Attach loose end of stainless steel chain to fixed eye bolt not supplied using the second stainless steel oval shaped threaded connecting link Alternate attachment method Wrap loose end of chain around fixed beam or other immovable support and create a closed loop using the second stainless steel oval shaped t...