14
Programming
Operates on a 24 hour cycle that begins from the time the START button is pushed. To start the cycle at
a specific time,
See the Schedule Advance Section on page 17.
Programmable Speed Settings:
3450, 3100, 2850, 2600, 2350, 2100, 1850, 1600, 1350, 1100, 850, 600, 0
NOTE: 0 is a programmable speed (RPM) and can be set for a specific duration.
Programmable Duration Settings (Hours)
24, 22, 20, 18, 16, 14, 12, 10, 8, 6, 4, 2, 0
Note: Up to three separate speeds with duration may be set. The sum of the three durations combined
must not exceed 24 hours. If the three combined exceed 24 hours, the pump will keep the current step
and re-write the remaining two steps to zero.
User can change the program duration and speed of STEP 1, STEP 2, STEP 3 & OVERRIDE keys.
Note: Pump must be
OFF
for programming speed and duration of the STEP 1, 2, 3 keys. Override speed
and duration can be programmed when the motor is
either
OFF or running.
Four programmable buttons lay across the top of the Keypad (overlay). (See Figure 4 - shows the speed
being set at 3100 RPM.) The LED directly above each button when lit indicates it is in operation or active.
To create a custom schedule and change the factory defaults settings, follow these steps:
1. Place the pump in the stop position (Press STOP Button).
2. Press the STEP 1 button. The LED above it will illuminate. The LED above the SPEED column will
illuminate.
3. Using the UP (+) or DOWN (-) arrows, toggle to the desired speed. The Bar graph will show the setting
as you toggle up and down. (See Figure 4 - shows the speed being set at 3100 RPM.)
4. Press the STEP 1 button again. The LED above the duration column will be lit.
5. Using the UP (+) or DOWN (-) arrows, toggle to the desired duration that you want this speed to run in
hours. The Bar graph will show the setting as you toggle up and down. (See Figure 5 - shows the duration
being set at 10 hours.)
6. Press any of the other STEP or the OVERRIDE button to save these settings for STEP 1.
7. To exit the system and not save these settings, press the STOP button.
8. Press STEP 2, STEP 3, or OVERRIDE key. Repeat steps 3-6 to program the corresponding speed and
duration for each button.