8
WARNING:
This product must be installed and serviced by a qualified pool professional, and must
conform to all national, state, and local codes. Before installing this product, read and follow all warning
notices and instructions of this product. Failure to follow warning notices and instructions may result in
property damage, personal injury, or death.
ATTENTION INSTALLERS:
This manual contains important information about the installation, operation,
and safe use of this product. This manual should be given to the owner/operator of this equipment.
1. Raypak recommends in order to achieve better priming, to install the pump as close to the pool as
practical and run suction lines as direct as possible to reduce friction loss.
2. It is recommended that a minimum length of straight pipe, equivalent to five (5) times the pipe diameter
be used between the pump suction inlet and any plumbing fittings (elbows, valves, etc.).
3. Install the pump on a level, solid foundation which provides a rigid and vibration-free base. Secure the
pump to the base with screws or bolts to further reduce vibrations and stress on the plumbing.
4. Protect the pump against flooding and excess moisture. Select an area that will not flood when it rains.
DO NOT
install the pump in a damp or non-ventilated location.
5. Keep the motor clean and provide free circulation of air for cooling.
6. Although the pump is designed for outdoor use, it is recommended to protect the pump from direct
sunlight and excessive moisture (rain, sprinklers, etc.).
7.
DO NOT
store or use gasoline or other flammable vapors or liquids in the vicinity of this pump.
DO NOT
store pool chemicals near the pump.
8.
DO NOT
remove any safety alert labels such as
DANGER, WARNING,
or
CAUTION
. Keep safety
labels in good condition and replace any missing or damaged labels.
9. Provide access for future services by leaving a clear area around the pump. Allow plenty of space
above the pump to remove lid and basket for cleaning.
WARNING:
Some Safety Vacuum Release System (SVRS) devices are not compatible with the installation
of check valves. If the pool has an SVRS device, be sure to confirm that it will continue to safely operate
when the check valves are installed.
NOTE: In Canada, the pump must be located a minimum of three (3) meters (approximately ten (10) feet)
from the water (CSA C22.1).
Pump Location
Pipe Sizing
NOTE: All pipe sizes are able to withstand the pressures the pump will deliver, but not necessarily the
flow. If the pipe is too small for the pump, or is elevated above water, the maximum gallons per minute
(GPM) may not be delivered. If this happens, the pump will develop a pocket of air (cavitation) that makes
noise. This may shorten the life of the pump.
SUCTION & DISCHARGE:
When the pump is located up to fifty (50) feet from the pool, the recommended minimum pipe size for both
the suction and discharge is 2”.