![Raypak PS165VSP Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/raypak/ps165vsp/ps165vsp_installation-operating-and-service-manual_791033032.webp)
27.1"
16.6"
17.0"
12.1"
12.7"
13.6"
8.9"
4.3"
6.8"
0.4"
5.1"
6.9"
9.7"
B
20
40
60
80 100 120 140 160
A
C
GALLONS PER MINUTE
TOT
AL
HEAD IN FEET
80
70
50
60
40
30
10
20
0
3450 RPM
3100 RPM
2850 RPM
2600 RPM
2350 RPM
2100 RPM
1850 RPM
1600 RPM
1350 RPM
1100 RPM
600 RPM
850 RPM
B, A, and C represent average system curves for pools
with the pipe diameter mentioned below.
B = 1
1
/
2
” Pipe A = 2” Pipe C = 2
1
/
2
” Pipe
32
Motor Replacement - continued
9. Remove the motor flange from the face of the old motor and install on the new motor.
10. Clean the surfaces of the seal
(Refer to the Removal and Replacement of the Impeller and/or
Mechanical Seal Section page 30-31 steps 9 -17)
. Reverse the process for installation.
7
Product Specifications
Dimensional Drawing
Performance Curve