![Raypak PS165VSP Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/raypak/ps165vsp/ps165vsp_installation-operating-and-service-manual_791033024.webp)
24
Heat Pump Pool Heater Connections (Wiring)
The PS165VSP can be connected directly to single phase or 3-phase Raypak, Rheem, Ruud, Weatherking
and Perfectemp Heat Pump Pool Heaters (HPPH) without the need for any external sequencer or
control. The HPPHs will provide an OVERRIDE signal to the pump whenever there is a Call for Heat at
the HPPH if wired as shown in these instructions. The pump will continue to operate at this OVERRIDE
speed until the HPPH thermostat has been satisfied.
NOTE: This direct wiring is ONLY available for R-410A Digital HPPH models produced after August
2010. The HPPH control board revisions PH2.8 and PH2.8D are the only revisions that provide this
connectivity. Verify the HPPH control board revision as shown in Figure 12 before attempting to connect
this pump to an existing Digital HPPH.
The PS165VSP pump will also connect to all Analog HPPH models (both R-410A and R-22) when
connected as shown in these instructions.
Figure 12 -
Digital HPPH Control Board Revision