Positive (+) bar
2
Negative (-) bar
3
Circuit breaker
4
Waterproof fuse holder containing a suitably-rated inline
fuse must be fitted. For suitable fuse rating, refer to:
In-line fuse and thermal breaker ratings
.
Important:
Observe the recommended fuse / breaker ratings provided in the product’s
documentation, however be aware that the suitable fuse / breaker rating is
dependent on the number of devices being connected.
Implementation — direct connection to battery
• Where connection to a power distribution panel is not possible, the power
cable supplied with your product may be connected directly to the vessel's
battery, via a suitably rated fuse or breaker.
• The power cable supplied with your product may NOT include a separate
drain wire. If this is the case, only the power cable’s red and black wires
need to be connected.
• If the power cable is NOT supplied with a fitted inline fuse, you MUST fit
a suitably rated fuse or breaker between the red wire and the battery’s
positive terminal.
• Refer to the inline fuse ratings provided in the product’s documentation.
• If you need to extend the length of the power cable supplied with your
product, ensure you observe the dedicated
Power cable extensions
advice
provided in the product’s documentation.
1
Waterproof fuse holder containing a suitably-rated inline
fuse must be fitted. For suitable fuse rating, refer to:
In-line
fuse and thermal breaker ratings
.
2
Product power cable.
3
Drain wire connection point.
Battery connection scenario A:
Suitable for a vessel with a common RF ground point. In this scenario, if your
product’s power cable is supplied with a separate drain wire then it should
be connected to the vessel’s common ground point.
Battery connection scenario B:
Suitable for a vessel without a common grounding point. In this case, if your
product’s power cable is supplied with a separate drain wire then it should
be connected directly to the battery’s negative terminal.