ST70+ User Reference Manual
7. Press
OK
to display the
Transducers found
menu.
8. If you have:
• A Wind transducer, carry out the
Wind
transducer setup
procedure below.
• A Speed transducer, carry out the
Speed
calibration
on
page 47
.
Wind transducer setup
The wind transducer setup procedures are used to:
•
Linearize the vane.
•
Align the vane.
•
Calibrate the wind speed.
Linearization
To linearize the wind vane:.
1. With the
Transducers found
menu displayed
(see
Preliminary procedure
on
page 45
), scroll
to the
Wind
option.
2. Press
OK
to select the
Wind
transducer setup
menu.
3. Scroll to the
Calibrate Vane
option.
4. Press
OK
to select the
Calibrate Vane
start
screen.
5. Keeping the boat speed below 2 knots and
observing the screen, turn the boat in circles,
then press
OK
to start the calibration.
6. Observe the
Calibrate Vane
run screen and
continue turning the boat:
• If the boat speed is too high during calibra-
tion, a
Slow down
message is displayed. If
this happens, reduce your speed.
• Calibration completes automatically.
7. When calibration is complete, the
Wind
transducer setup menu is displayed.
i
D1
1
174-1
Transducers Found
Depth
Raymarine
Serial no.135260
Press OK to select
i
D1
121
1-1
Transducers found
Wind
Raymarine
Serial no.176342
Press OK to select
i
D1
1212-1
Wind
Calibrate Vane
Raymarine
Serial no.176342
Press OK to select
i
D1
1213-1
Press OK to continue
Calibrate Vane
Move in a slow circle, below 2kts.
Watch for 'too fast' on display.
87099_1.book Page 46 Thursday, March 12, 2009 10:18 AM
Содержание ST70 Instrument
Страница 1: ...www raymarine com ST70 Document reference 87099 1 Date January 2009 Installation Guide ...
Страница 6: ...vi ...
Страница 10: ...x ST70 Installation Guide ...
Страница 20: ...10 ST70 User Reference Manual ...
Страница 28: ...18 ST70 User Reference Manual ...
Страница 64: ...54 ST70 User Reference Manual ...
Страница 70: ...60 ...
Страница 72: ...62 ...