Raymarine drive compatibility X 10 X
30 X SOLENOID
SPX-10
• all Type 1 drives/pumps (excluding
CR pumps). Drive voltage must
match boat’s supply voltage.
SPX-30
• all Type 1, Type 2 and Type 3 drives
/ pumps. Drive voltage must match
boat’s supply voltage.
SPX-SOL
• CR pumps and solenoid drive
Drive current output
SPX-10
• Continuous 10A at supply voltage
• Peak (Limit) 25 A
• Continuous 30A at supply voltage
(SPX-30)
SPX-30
• Continuous 30A at supply voltage
(SPX-30)
• Peak (Limit) 50 A
Drive clutch output X 10 X 30 X
SOLENOID
• 2.0 A at 12 / 24 V selectable
(SPX-10, SPX-SOL)
• 3.0 A at 12 / 24 V selectable
(SPX-30)
EMC compliance:
• Europe: 2004/108/EC
• Australia and New Zealand: C-Tick,
Compliance Level 2
Appendix B NMEA 0183 sentences
SPX course computers with an NMEA 0183 input/output support
the following sentences.
Receive (NMEA 0183 in)
APB
Autopilot B
BWC
Bearing and distance to waypoint
BWR
Bearing and distance to waypoint
rhumb line
GGA
Global positioning system fix data
GLL
Geographic position latitude longitude
HDG
Heading deviation and variation
HDM
Heading magnetic
HDT
Heading true
MWV
Apparent wind angle and speed
RMA
Recommended minimum specific
Loran C data
RMB
Recommended minimum navigation
information
RMC
Recommended minimum specific
GPS transit data
VHW
Speed through water and heading
VTG
Course over ground (COG) and speed
over ground (SOG)
XTE
Cross track error
ZDA
Time and date
46
SPX SmartPilot installation instructions
Содержание SmartPilot SPX-10
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ...6 SPX SmartPilot installation instructions ...
Страница 10: ...10 SPX SmartPilot installation instructions ...
Страница 40: ...40 SPX SmartPilot installation instructions ...
Страница 44: ...44 SPX SmartPilot installation instructions ...
Страница 49: ......
Страница 50: ...www raymarine com ...