3.10 Compass connection
The fluxgate compass connects to the course computer connection
panel as shown.
P
O
W
E
R
,
1
5
A
M
P
12V
24V
FLUXGATE
RUDDER
CLUTCH
FAULT
S LEEP
NMEA
D
10461-2
3
4 5
1 2
< 200 mm
(7.8 in)
Connection colors
The compass is supplied with an 8 m (26 ft) flying lead.
Color
1
Grey (screen)
2
Red
3
Green
Color
4
Yellow
5
Blue
Cable suppression ferrite
A suppression ferrite is supplied to ensure that the compass is not
unduly affected by interference and complies with applicable EMC
regulations. This must be fitted to the fluxgate compass cable,
ensuring that:
• the compass cable loops twice through the ferrite,
• the ferrite is no more than 200 mm (8 in) from the connection at
the course computer, and
• is held in position by cable ties at each end.
Cables and connections
35