14
Object
Description
Value
A
External diameter
12mm to 18mm
B
Copper conductor cross-section
4mm² to 10mm²
C
Stripping length of the insulated conductors
approx. 13mm
D
Stripping length of the outer sheath of the AC cable
approx. 53mm
The PE conductor must be 10mm longer than the L and N conductors
b. Insert the conductor into the suitable ferrule acc. to DIN 46228-4 and crimp the contact.
b
c. Unscrew the swivel nut from the threaded sleeve and thread the swivel nut and threaded sleeve over the AC cable.
c
d. Insert the crimped conductors L, N and PE into the corresponding terminals and tighten the screw with a hex key
wrench screwdriver (size:2.5, 1.2-2.0Nm). Ensure that all conductors are securely in place in the screw terminals on
the bush insert.
d
e. Screw the swivel nut onto the threaded sleeve. This seals the AC connector and provides strain relief for the AC
cable. When doing so, hold the bush insert firmly by the locking cap. This ensures that the swivel nut can be screwed
firmly onto the threaded sleeve.
e
f. Assembly the plug shell, adapter as
below picture, Push the adapter and Shell by hand until a “Click” is heard or felt.
F
L
N
G