Rayleigh Instruments RI-ENERGY 3.0D Скачать руководство пользователя страница 24

24 

 

 

 

If the inverter displays any alarm message as listed in the previous table; please turn off 
the  inverter  (refer  to  Section  5.2  to  stop  your  inverter)  and  wait  for  5  minutes  before 
restarting it (refer to Section 5.1 to start your inverter). If the failure persists, please contact 
your  local  distributor  or  the  service  centre.  Please  keep  ready  with  you  the  following 
information before contacting us. 

 

1. Serial number of RI-ENERGYFLOW-MIDI Single Phase Inverter;  
2. The distributor/dealer of RI-ENERGYFLOW-MIDI Single Phase Inverter (if available);  
3. Installation date.  
4.  The description  of  the problem  (i.e.  the alarm  message  displayed  on  the LCD  and  the status  of  the  LED 
status indicator lights. Other readings obtained from the Information submenu will also be helpful.)

 

5. The PV array configuration (e.g. number of panels, the capacity of panels, number of strings,etc.);  
6. Your contact details. 

 

9. Specifications 

 

Model - RI-ENERGYFLOW-MIDI- 

3.0D 

3.6D 

4.0D 

4.6D 

5.0D 

6.0D 

DC Input Data 

  Max. DC power (W) 

4050 

4860 

5400 

6210 

6750 

8100 

Max./Rated DC voltage(V) 

600V / 380V 

Min. / Start DC voltage(V) 

120V / 100V 

MPPT voltage range(V) 

80V-550V 

Number of MPPT 

Strings per MPPT 

Max. input current per MPPT(A) 

    15 

AC Output Data 

Rated AC output power(W) 

3000 

3600 

4000 

4600 

5000 

6000 

Max. AC output power(VA) 

3300 

3960 

4400 

5060 

5500 

6600 

Max. output current(A) 

14.4 

17 

19 

22 

24 

26 

Rated AC voltage(V) 

230Vac±20% 

AC voltage range(V) 

230Vac 

Rated AC grid frequency(Hz) 

50 / 60Hz 

AC grid frequency range(Hz) 

50 / 60Hz(±5Hz) 

Power Factor (cos Φ) 

                                0.8 leading ~ 0.8 lagging 

THDi 

<3%

 

Efficiency 

Max.Efficiency 

98.1%

 

98.3% 

Euro Efficiency 

97.7%

 

97.9%

 

Protection 

Anti-island Protection 

Integrated 

Output over current protection 

Integrated 

Output short protection 

Integrated 

DC reverse-polarity protection 

Integrated 

General Data 

Size(Width*Height*Depth) 

380 x 380 x 150 

Weight(kg) 

                                               11                                                  

User Interface 

LED & LCD 

Communication 

        RS485 / Wi-Fi / 4G 

Ambient Temperature Range 

-25 

 ~ 60 

 

Relative Humidity 

0-100% 

Operating Altitude 

≤4000m 

Standby Self Consumption 

<0.2W 

Topology 

Transformerless 

Cooling 

Natural Cooling 

Protection Grades 

IP65 

Содержание RI-ENERGY 3.0D

Страница 1: ...yleigh Instruments Limited Head Office RaytelHouse CutlersRoad SouthWoodhamFerrers Chelmsford EssexCM35WA UK E Sales Rayleigh com Rayleigh Instruments Limited SP Z o o European Office Ul Aleje Jerozol...

Страница 2: ...2...

Страница 3: ...nt Panel Display 8 3 2 LED Status Indicator Light 8 3 3 Keypad Optional 8 3 4 LCD Optional 9 4 Installation 9 4 1 Select a Location for the Inverter 9 4 2 Mounting the Inverter 10 4 3 Electrical Conne...

Страница 4: ...LOW MIDI 3 0D 3 6D 4 0D 4 6D 5 0D 6 0D Figure 1 1 Front and side view Figure 1 2 Bottom side view Object Description DVC class 1 PV1 PV2 DVC C 2 AC OUTPUT DVC C 3 DRM DVC A 4 CT DVC A 5 COM DVC A 1 2...

Страница 5: ...RM connector 1 2 CT connector 1 3 WiFi GPRS Stick 1 4 1xCT and com cable 1 2 Safety instructions Please read the safety instructions in this manual Throughout the manual it is assumed that the reader...

Страница 6: ...portant for the protection of property Violation of this type of information may cause damage and loss of property RoHS Useful additional information or Tips and Tricks on specific subjects ROHS Mark...

Страница 7: ...ed personnel are allowed to repair or modify the inverter To ensure optimum safety for user and environment only the original spare parts available from your supplier should be used Functional safety...

Страница 8: ...n the indicator light is green it indicates the operation state Light Status Description ON Alarm or fault condition is detected ON The inverter is operating properly Flashing Grid Connected countdown...

Страница 9: ...direct sunlight or raining To avoid overheating ambient air temperature must be considered when choosing the inverter installation location Rayleigh Instruments recommends using a sunshade to minimise...

Страница 10: ...e 4 3 Inverter wall mounting Please see Figure 4 4 and Figure 4 5 for instructions on mounting the inverter The inverter shall be mounted vertically The steps to mount the inverter are listed below 1...

Страница 11: ...ure 4 5 Figure 4 5 Wall Mount Bracket 5 Use M5 16 screws in the accessory to lock the inverter to the mount bracket 4 3 Electrical Connections 4 3 1 Connect PV side of inverter The electrical connecti...

Страница 12: ...ion Range Recommended value Industry generic PV cable model PV1 F 4 0 6 0 12 10AWG 4 0 12AWG Table 4 1 DC cable The steps to assemble the DC connectors are listed as follows I Strip off the DC wire fo...

Страница 13: ...lick will confirm the connection Figure 4 11 Connect the DC Connectors to the Inverter 4 3 2 Connect grid side of the inverter For all AC connections 4 10mm 105 XJ cable is required to be used Please...

Страница 14: ...threaded sleeve over the AC cable c d Insert the crimped conductors L N and PE into the corresponding terminals and tighten the screw with a hex key wrench screwdriver size 2 5 1 2 2 0Nm Ensure that...

Страница 15: ...e right side of inverter Prepare OT terminals M5 Use proper tooling to crimp the lug to the terminal Figure 4 18 Connect the external grounding conductor When an earth fault occurs the machine cannot...

Страница 16: ...urrent A Current for protection device A 3 0D 380 15 20 3 6D 380 15 20 4 0D 380 15 20 4 6D 380 15 20 5 0D 380 15 20 6 0D 380 15 20 Table 4 4 Rating of PV OCPD 4 3 5 Inverter monitoring connection The...

Страница 17: ...optional This inverter has integrated export limitation functionality To use this function a CT must be installed if use the CT please reference the picture below The CT should be fitted around the l...

Страница 18: ...d to support demand response mode DRM This function is for the inverter that complies with AS NZS 4777 2 2015 standard RI ENERGYFLOW MIDI single phase inverter fully complies with all DRM A 6P termina...

Страница 19: ...the green LED will flash and the LCD displays the information of INITIALIZING 4 After 20 300 seconds depending on local requirement the inverter will start to generate power The green LED will be on c...

Страница 20: ...the ESC key to access to the Main Menu there are three submenus in the Main Menu see Figure 6 3 Figure 6 3 Main Menu 6 1 Setup Technicians Only To access this area is for fully qualified and accredit...

Страница 21: ...he following information You can also continue to access the next menu level Password can be changed through item 11 Figure 6 5 Setup menu POWER FACTOR mode is selected by default and QU WAVE or other...

Страница 22: ...ot and cause burns Turn off the inverter refer to Section 5 2 and wait for a cool down period before any maintenance or cleaning operation The LCD and the LED status indicator lights can be cleaned wi...

Страница 23: ...t of working temperature F13 Heatsink Temperature High 1 Disconnect PV input and cool down the inverter then restart the inverter to see if it is back to normal operation 2 Please check environmental...

Страница 24: ...0D 3 6D 4 0D 4 6D 5 0D 6 0D DC Input Data Max DC power W 4050 4860 5400 6210 6750 8100 Max Rated DC voltage V 600V 380V Min Start DC voltage V 120V 100V MPPT voltage range V 80V 550V Number of MPPT 2...

Страница 25: ...legible Otherwise Rayleigh Instruments has the right to refuse to honour the quality guarantee Conditions After replacement unqualified products shall be processed by Rayleigh Instruments The custome...

Страница 26: ......

Страница 27: ...ted Raytel House Cutlers Road South Woodham Ferrers Chelmsford Essex CM3 5WA UK Email sales rayleigh com W www Rayleigh com Rayleigh Instruments Limited SP Z o o European Office Ul Aleje Jerozolimskie...

Отзывы: