Noise 

<25dB 

Warranty 

5 /7/10 years 

Optional 

                   DC Switch / WiFi Plug / GPRS Plug 

AC Output terminal type 

                                    Quick connector 

Certifications & Standards 

Grid Regulation 

IEC61683, IEC60068, IEC60529, EC62116, IEC61727, EN50549-

1, AS4777, NRS 097, VDE-AR-N-4105, VDE 0126-1-1, CEI0-21, 

G98, G99, C10/C11, TED749, UNE217001, UNE217002, 

NB/T32004-2018, GB/T19964-2012, INMETRO 

Safety Regulation 

IEC 62109-1, IEC 62109-2 

EMC 

IEC/EN61000-6-2, IEC/EN6100-6-4 

 

10. Quality Assurance  

 

Once the product has been installed and operational, it is paramount to register the product to initiate the 

Warranty cover, without this, your product would not be covered under our warranty scheme. Please follow 

this web link for the full procedure: 

https://www.rayleigh.com/warranties/ 

 

When  product  faults  occur  during  the  warranty  period,  Rayleigh  Instruments  or  his  partner  will  provide  free 
service or replace the product with a new one.  
 

Evidence

 

 

During the warranty period, the customer shall provide the product purchase invoice and date. In addition, the 
trademark on the product shall be undamaged and legible. Otherwise, Rayleigh Instruments has the right to 
refuse to honour the quality guarantee.  
 

Conditions 
 

• After replacement, unqualified products shall be processed by Rayleigh Instruments.  
• The customer shall give Rayleigh Instruments or his partner a reasonable period to repair the faulty device.  
 

Exclusion of Liability  
 

In the following circumstances, Rayleigh Instruments has the right to refuse to honour the quality guarantee:  
• The free warranty period for the whole machine/components has expired.  
• The device is damaged during transport.  
• The device is incorrectly installed, refitted, or used.  
• The device operates in a harsh environment, as described in this manual.  
• The fault or damage is caused by installation, repairs, modifications, or disassembly performed by a service 
provider or personnel, not from Rayleigh Instruments or his authorized partner.  
• The fault or damage is caused by the use of non-standards 
 

components or software. 
 

• The installation and use range are beyond stipulations of relevant international standards.  
• The damage is caused by unexpected natural factors. For faulty products in any of the above cases, if the 
customer requests maintenance, paid maintenance service may be provided based on the judgment of Rayleigh 
Instruments. 

Содержание RI-ENERGY 3.0D

Страница 1: ...yleigh Instruments Limited Head Office RaytelHouse CutlersRoad SouthWoodhamFerrers Chelmsford EssexCM35WA UK E Sales Rayleigh com Rayleigh Instruments Limited SP Z o o European Office Ul Aleje Jerozol...

Страница 2: ...2...

Страница 3: ...nt Panel Display 8 3 2 LED Status Indicator Light 8 3 3 Keypad Optional 8 3 4 LCD Optional 9 4 Installation 9 4 1 Select a Location for the Inverter 9 4 2 Mounting the Inverter 10 4 3 Electrical Conne...

Страница 4: ...LOW MIDI 3 0D 3 6D 4 0D 4 6D 5 0D 6 0D Figure 1 1 Front and side view Figure 1 2 Bottom side view Object Description DVC class 1 PV1 PV2 DVC C 2 AC OUTPUT DVC C 3 DRM DVC A 4 CT DVC A 5 COM DVC A 1 2...

Страница 5: ...RM connector 1 2 CT connector 1 3 WiFi GPRS Stick 1 4 1xCT and com cable 1 2 Safety instructions Please read the safety instructions in this manual Throughout the manual it is assumed that the reader...

Страница 6: ...portant for the protection of property Violation of this type of information may cause damage and loss of property RoHS Useful additional information or Tips and Tricks on specific subjects ROHS Mark...

Страница 7: ...ed personnel are allowed to repair or modify the inverter To ensure optimum safety for user and environment only the original spare parts available from your supplier should be used Functional safety...

Страница 8: ...n the indicator light is green it indicates the operation state Light Status Description ON Alarm or fault condition is detected ON The inverter is operating properly Flashing Grid Connected countdown...

Страница 9: ...direct sunlight or raining To avoid overheating ambient air temperature must be considered when choosing the inverter installation location Rayleigh Instruments recommends using a sunshade to minimise...

Страница 10: ...e 4 3 Inverter wall mounting Please see Figure 4 4 and Figure 4 5 for instructions on mounting the inverter The inverter shall be mounted vertically The steps to mount the inverter are listed below 1...

Страница 11: ...ure 4 5 Figure 4 5 Wall Mount Bracket 5 Use M5 16 screws in the accessory to lock the inverter to the mount bracket 4 3 Electrical Connections 4 3 1 Connect PV side of inverter The electrical connecti...

Страница 12: ...ion Range Recommended value Industry generic PV cable model PV1 F 4 0 6 0 12 10AWG 4 0 12AWG Table 4 1 DC cable The steps to assemble the DC connectors are listed as follows I Strip off the DC wire fo...

Страница 13: ...lick will confirm the connection Figure 4 11 Connect the DC Connectors to the Inverter 4 3 2 Connect grid side of the inverter For all AC connections 4 10mm 105 XJ cable is required to be used Please...

Страница 14: ...threaded sleeve over the AC cable c d Insert the crimped conductors L N and PE into the corresponding terminals and tighten the screw with a hex key wrench screwdriver size 2 5 1 2 2 0Nm Ensure that...

Страница 15: ...e right side of inverter Prepare OT terminals M5 Use proper tooling to crimp the lug to the terminal Figure 4 18 Connect the external grounding conductor When an earth fault occurs the machine cannot...

Страница 16: ...urrent A Current for protection device A 3 0D 380 15 20 3 6D 380 15 20 4 0D 380 15 20 4 6D 380 15 20 5 0D 380 15 20 6 0D 380 15 20 Table 4 4 Rating of PV OCPD 4 3 5 Inverter monitoring connection The...

Страница 17: ...optional This inverter has integrated export limitation functionality To use this function a CT must be installed if use the CT please reference the picture below The CT should be fitted around the l...

Страница 18: ...d to support demand response mode DRM This function is for the inverter that complies with AS NZS 4777 2 2015 standard RI ENERGYFLOW MIDI single phase inverter fully complies with all DRM A 6P termina...

Страница 19: ...the green LED will flash and the LCD displays the information of INITIALIZING 4 After 20 300 seconds depending on local requirement the inverter will start to generate power The green LED will be on c...

Страница 20: ...the ESC key to access to the Main Menu there are three submenus in the Main Menu see Figure 6 3 Figure 6 3 Main Menu 6 1 Setup Technicians Only To access this area is for fully qualified and accredit...

Страница 21: ...he following information You can also continue to access the next menu level Password can be changed through item 11 Figure 6 5 Setup menu POWER FACTOR mode is selected by default and QU WAVE or other...

Страница 22: ...ot and cause burns Turn off the inverter refer to Section 5 2 and wait for a cool down period before any maintenance or cleaning operation The LCD and the LED status indicator lights can be cleaned wi...

Страница 23: ...t of working temperature F13 Heatsink Temperature High 1 Disconnect PV input and cool down the inverter then restart the inverter to see if it is back to normal operation 2 Please check environmental...

Страница 24: ...0D 3 6D 4 0D 4 6D 5 0D 6 0D DC Input Data Max DC power W 4050 4860 5400 6210 6750 8100 Max Rated DC voltage V 600V 380V Min Start DC voltage V 120V 100V MPPT voltage range V 80V 550V Number of MPPT 2...

Страница 25: ...legible Otherwise Rayleigh Instruments has the right to refuse to honour the quality guarantee Conditions After replacement unqualified products shall be processed by Rayleigh Instruments The custome...

Страница 26: ......

Страница 27: ...ted Raytel House Cutlers Road South Woodham Ferrers Chelmsford Essex CM3 5WA UK Email sales rayleigh com W www Rayleigh com Rayleigh Instruments Limited SP Z o o European Office Ul Aleje Jerozolimskie...

Отзывы: