Vi5004 PoE Media Converter Installation Manual
Application Drawing
Media Converter
Important Safety Warning
WARNING! - To reduce the risk of fire or electric shock, do not expose
this apparatus to rain or moisture. This apparatus shall not be exposed to
dripping or splashing and no objects filled with liquids, such as vases shall
be placed on the apparatus.
WARNING! - This apparatus is a Class I product. This product must
be connected to a mains socket outlet thru an AC to DC Power supply.
WARNING! - The mains plug is used as the disconnect device and
shall remain readily operable.
DO NOT OPEN
RISK OF ELECTRIC SHOCK
CAUTION
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
IP Camera-end Installation
The Smart Choice for Transmission Solutions
www.vigitron.com
Ethernet Switch/NVR-end Installation
- Connect an approved 12VDC power supply to the power connector of
Vi5004. A power adapter connector is provided to simplify connection.
- Connect the RJ45 connector of the Ethernet switch to the 10/100BaseT
Ethernet port of Vi5004 using a standard Cat5/6 cable of maximum
328 feet (100 m) in length.
- Connect one end of the long fiber optic cable to a SFP module, then
connect the SFP module to the SFP socket of Vi5001.
The Ethernet link, Fiber link, activity LEDs should be "ON" and "Blink" to
indicate the status of each port.
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with a dry cloth.
- Install in accordance with the manufacturer’s instructions.
- This installation should be made by a qualified service person and should
conform to all local codes.
- DO NOT bundle UTP or Coax signals in the same conduit as high-voltage
wiring.
- To reduce the risk of fire or electrical shock, do not expose these products
to rain, moisture, dripping or splashing.
- No objects filled with liquids, such as vases, shall be placed on Vigitron
equipment.
- DO NOT install the unit in a place where the operating ambient tempera
ture exceeds 75° C.
- Make sure that the external power supply output voltage is in the recom
mended range.
- Do not install near any heat sources such as radiators, heat registers,
stoves or other apparatus (including DVRs) that produce heat.
- Protect the power cord from being walked on or pinched particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.
- Only use attachments/accessories specified by the manufacturer.
- Unplug this apparatus during lightning storms or when unused for long
periods of time.
- Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as a power
supply cord or plug is damaged, liquid has been spilled, or objects have
fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
- The powe plug is used as the disconnect device and shall remain readily
operable.
Vigitron’s Vi5004 is a 4 channels media convertor that enables Ethernet
signals to be transmitted over different fiber optic cables UTP connections
with fiber to meet long distance transmission requirement and those where
fiber is already installed. The use of SFP fiber modules results in compat-
ibility with all major single and multimode fiber optics cables to achieve
transmission distances depending on the cable and SFP. When connected
to the Vi5001, up to 30 watts PoE can be provided to site cameras using
the Vi0017 power supply.
The Vi5004 can also be connected directly to MSA compliant SFP.
The Vi5004 is an ideal solution forconverting existing analog fiber
infrastructures to IP systems. It provides a unique, reliable, and cost
effective solution to combine a variety of transmission methods to meet any
application requirement. By using the Vi5000R, up to four Vi5004 modules
can be used to provide up to 16 channels of Ethernet copper to fiber
conversion in a rack mount configuration.
- Insert a suitable 100MBps SFP into the SFP socket of the Vi5001. The
SFP needs to match the specification of the fiber optics cable.
- Connect the fiber connector of the optical wire to the SFP.
- If the IP Camera is non-PoE use an approved 12VDC or 48VDC power
adapter to power the Vi5001.
- If the IP Camera is a PoE enabled use the Vi0017 or another approved
48VDC power adapter to power the Vi5001.
- Connect the IP camera RJ45 connector to the “10/100BaseT Ethernet” port
of Vi5001 using a standard Cat5/6 cable of maximum 100m in length.
Vi0012
Vi0017
PoE Camera
Vi3026/Vi3326
Vi5001
Fiber
Data & PoE
Vi0012
Vi5004
SFP
+
SFP x4
+
Vi0017
PoE Camera
Vi3005
Vi5001
Data & PoE
Vi5004
SFP
SFP x4
+
Fiber
Vi0012