Quick Installation Guide

MPEG-2 & 1 ENCODER

1

or

Getting Started

The Encoder’s IP address, as well as basic video settings, are required as the video channels are disabled when shipped 

from the factory. These configuration settings are set via the serial interface or a Telnet session. Once the IP address is set, 

the configuration can proceed using the serial interface, Telnet, Impath i-Volution NMS or via an SNMP manager.

Serial local console access

Requirements:

    PC workstation with a RS 232 serial interface

    PC workstation capable of running terminal emulation program. (example, Windows HyperTerminal).

    PC serial cable - DB9 Male to Female. This cable is available from any PC supply store

        Set the Terminal Emulation application for 9600 bps, 8 bit, no parity on appropriate COM port.

    Connect the serial cable between the Encoder serial Port “A” (also labeled Console) and your workstation COM port.

    Start the Terminal Emulator (Windows Hyper Terminal) application

    Press and hold the “console” button on the unit for 6 to 8 seconds until the data LED on the unit turns amber (yellow)

    At this time, the message “CONSOLE>” will appear on the workstation screen.

    At the CONSOLE> prompt enter “

maint

” 

<ENTER>

    The “MAIN MENU” prompt will appear.

    Go to step 2

Telnet console access

Requirements:

    PC Workstation with an Ethernet interface (10/100BaseT)

    PC Workstation must be connected to the Ethernet network using a valid IP address for the Ethernet network.

    If connected directly to the Encoder, a crossover Ethernet cable is required

    NOTE: After each entry, press the 

<ENTER>

 key on the PC keyboard.

    Use Windows Start > RUN to launch a Telnet session.

        Enter “

telnet _ _ _ . _ _ _ . _ _ _ . _ _ _

” Enter the Encoder IP address

    At the “LOGIN” prompt, enter the username. The default value is “

impath

    At the “Password” prompt, enter the unit password. The default value is “

impath

    At the “REMOTE-CON>>” prompt, enter “

maint

    The “MAIN MENU” prompt will appear.

    Go to step 2

VSG-L

VSG

i1000, i1200, i1400

i4000

Locate “Console” button

in front of Encoder

Connect to Port A

of Encoder

DB9 serial cable

Connect to

COM port

PC Workstation

Terminal Emulation Application

9600 Bps, 8 bit, no parity

No flow control

VSG-L

VSG

i1000, i1200, i1400

i4000

Ethernet RJ 45 port

Ethernet Cable

Connect Ethernet

cable to RJ 45

Ethernet ports

PC Workstation

From the Windows Start menu

select RUN and type in

telnet <IP address>