4.3. Settings Tab
4.3.1. Global Load & IV Curve Control
The load control mode (peak-power, voltage tracking, or off) can be set individually for
each module or globally for all modules (see Figure 12). Refer to section 4.3.2
“Module
Channel Settings” for individual module channel settings. Global control settings
override the individual settings. There are separate settings for continuous load
operation and IV curves.
Figure 14. Global load & IV curve modes.
Global Load Mode
This setting controls how all the module loads operate while collecting performance
data.
•
All Loads Off
– Turns all loads off (open circuit) regardless of individual module
channel setting.
•
All Peak Power
– Sets all modules to peak power track, regardless of module
channel setting.
•
All Fixed Voltage
– Sets all modules to operate at a fixed voltage. The fixed voltage
is separately set for each module in the module channel settings.
•
Channel Defined
– Operate the module load as defined for that individual module
channel.