Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus RFL-A4000D~A12000D
31
5.1
ON Mode
In the ON mode, the user can send commands to set different working modes through computer
software or direct communication. After the laser is powered on again, the mode before power failure will
be memorized.
5.1.1
AD Enable Mode
When AD mode is enabled, the laser power is determined by the analog voltage of pin 1 and pin 2 of
XP4; if the AD mode is not enabled, the laser power can be set through the computer software or send the
"SDC XX" command.
5.1.2
Emission External Control Enable
When the external control is enabled, the laser emission is determined by the MOD level state on the
pin 1 and pin 2 of XP2; If the external control emission is not enabled, the laser emission and shutdown
are determined by the light output button of the computer software, or communication sends "EMON" to
control the laser emission and send "EMOFF" to control the laser off.
5.1.3
Red Light Control
In the ON mode, the red light can only be turned on by sending "ABN" through the computer
software or communication, and "ABF" turns off red light. The red-light module in the laser works by
means of communication, so there is a time delay of at least 10 MS when the red light is turned on and off.
When the red light is on, the laser cannot be set to Ready position. Only when the red light is off, can the
laser be ready.
5.1.4
Programming Mode
In the ON mode, when the current program number of the laser is not 0, the laser will run in the
programming mode.
Please use the computer software of Raycus to edit the wave and select the pre-operation program
number.
When the laser is in the emission internal control mode, press
or send EMON
command
,
the laser starts to operate program; send or press EMOFF,
the laser can stop
program at any time;
When the laser is in the external control mode, the rising edge of MOD starts to operate the program,
and the falling edge of MOD can terminate the program at any time.