Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus RFL-A4000D~A12000D
40
6.7
Programming mode in REM mode
Figure 28 Wiring diagram of programming mode on REM mode
Operation methods:
a)
The rear panel air switch hits ON to supply power to the laser.
b)
Front panel key switch to REM, the laser into REM mode.
c)
Shorting pin 8 and pin 9 on XP2 to supply power to the main control board.
d)
XP1-A1 is connected to 24V.
e)
XP1-A5 is connected to 24V to turn on the red light; XP1-A5 is connected to 0V to turn off the
red light after checking the optics.
f)
XP1-C1 is connected to 24V, and the main power is turned on (you can also press the LASER
button directly, or the upper computer software points the main power ON).
g)
Wait for the laser tricolor light to turn on green, the laser preparation is completed.
h)
XP1-(A8-14) select the pre-executed program number, XP1-A2 set to high to start the execution
of the program.