Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus RFL-A4000D~A12000D
37
6.5
Set the power analog as emission external control on the REM mode
Figure 25 Wiring diagram of setting the power analog as emission external control on the REM mode
Operation methods:
a)
The rear panel air switch hits ON to supply power to the laser.
b)
Front panel key switch to REM, the laser into REM mode.
c)
Shorting pin 8 and pin 9 on XP2 to supply power to the main control board.
d)
XP1-A1 is connected to 24V and XP1-A6 is connected to 24V to enter the external control analog
mode.
e)
XP1-A5 is connected to 24V to turn on the red light.XP1-A5 is connected to 0V to turn off the red
light.
f)
XP1-C1 is connected to 24V, and the main power is turned on (you can also press the LASER
button directly, or the upper computer software points the main power ON).