Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus RFL-A4000D~A12000D
36
6.4
Emission external control through programming mode on the ON mode
Figure 24 Wiring diagram of Emission external control through programming mode on the ON mode
Operation methods:
a)
The rear panel air switch hits ON to supply power to the laser.
b)
The front panel key switch is turned ON to put the laser into ON mode.
c)
Open the upper computer software.
d)
Click the red ON button to view the red light.
e)
Click the main power ON button in the upper computer software to turn on the main power.
f)
Wait for the laser tricolor light to turn on green and the laser preparation is completed.
g)
Set the waveform number for pre-execution (program number is greater than 0).
h)
Start the waveform on the rising edge of the external MOD signal.
i)
Check that the red light of the laser tricolor lamp is on, and the laser is outputting light.
Note: high level time of MOD must be more than program operation; if MOD gives the falling edge
in advance, the computer software will show that the laser program is stopped abnormally.