Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-A6000D~10000D
49
DEC
Disable External Control
Send: ‘DEC\r’
Return: ‘DEC\r’
EEC
Enable External Control
Send: ‘EEC\r’
Return: ‘EEC\r’
DLE
Disable Hardware Emission Control
Send: ‘DLE\r’
Return: ‘DLE\r’
ELE
Enable Hardware Emission Control
Send: ‘ELE\r’
Return: ‘ELE\r’
EM
OFF
Stop Emission
Send: ‘EMOFF\r’
Return: ‘EMOFF\r’
EM ON
Start Emission
Send: ‘EMON\r’
Return: ‘EMON\r’
MPWR
OFF
Main Power OFF
Send: ‘MPWROFF\r’
Return: ‘MPWROFF\r’
MPWR
ON
Main Power ON
Send: ‘MPWRON\r’
Return: ‘MPWRON\r’
SPW
Set Pulse Width
Send: ‘SPW 100\r’
Return: ‘SPW:100\r’
(
Set pulse width as 100ms
)
Other return values:
‘ERR: input Err\r’
(
Input pulse width
<
0.0001
)
‘ERR: Out of Range\r’
(
Over maximum pulse width
)
‘ERR: Duty Cycle too High\r’
SPRR
Set Pulse Repetition Rate
Send: ‘SPRR 1000\r’
Return: ‘SPRR
:
1000\r’
‘ERR: input Err\r’
‘ERR: Out of Range\r’
‘ERR: Duty Cycle too High\r’
‘ERR: Duty Cycle too Low\r’
‘SPW: 100, Duty=100%\r’