Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-A6000D~10000D
36
9
XP1-A1is high level
,
XP1-A3 is low level and suspending;
10
XP1-A1is high level
,
XP1-A8~A14 is not all low level;
11
Emit laser: Communication sends
“
EMON” or computer software
clicks
button.
Turn off the laser: communication sends
“
EMOFF”, or computer software
clicks
button.
12
Communication sends
“
ABN” or computer software clicks
button to emit
red light,
communication sends
“
ABF” or computer software clicks
button to turn off
the red light.
13
The communication sends "SDC XX" to set the power percentage, XX represents the power
percentage, or the computer software clicks
button;
5.1 ON Mode
In the ON mode, the user can send commands to set different working modes through computer
software or direct communication. After the laser is powered on again, the mode before power failure
will be memorized.
5.2 AD Enable Mode
When AD mode is enabled, the laser power is determined by the analog voltage of pin 1 and pin
2 of xp4; if the AD mode is not enabled, the laser power can be set through the computer software or
send the "SDC XX" command.
5.2.1 Emission External Control Enable
When the external control is enabled, the laser emission is determined by the MOD level state
on the pin 1 and pin 2 of xp2; If the external control emission is not enabled, the laser emission and