Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-A6000D~10000D
44
Operation methods
:
a) The rear panel air switch hits ON to supply power to the laser.
b) Front panel key switch to REM, the laser into REM mode;
c) Shorting pin 8 and pin 9 on XP2 to supply power to the main control board.
d) XP1-A1 is connected to 24V and XP1-A6 is connected to 24V to enter the external control
analog mode.
e) XP1-A5 is connected to 24V to turn on the red light; after checking the optics, XP1-A5 is
connected to 0V to turn off the red light.
f) XP1-C1 is connected to 24V, and the main power is turned on (you can also press the LASER
button directly, or the upper computer software points the main power ON).
g) Wait for the green light of the laser tricolor lamp to light up, and the laser preparation work is
completed.
h) XP1-A2 is connected to 24V, and the control board outputs analog and MOD signals.
I) Check that the red light of the laser tricolor lamp is on, and the laser is outputting
light.
Figure 24 timing diagram of setting power analog as emission external control signal on REM mode