The displayed information will look similar to this
:
The basic criteria for a proper fucntionning of the load sensor are:
the
scale value must be smaller than 1,0.
Dr+
must be close to 5,00
volts (DC).
Press the
Escape
button to go back to the main screen of the
diagnostic mode.
5.3 Load Sensor (Cont’d)