If you have any questions or need assistance, please contact the
RaycoWylie
technical assistance
department.
5.5 Error messages
5.5.1 Internal peripherals
Error message
Runtime process
Error cause
Read calibration
Read canbus config.
Read logger
Read absolute limiter
During start-up, the system
runs an integrity check of all
the data in the flash memory
(CRC).
There is a problem with the flash
memory of the system in the display
of the i4000.
Contact the RaycoWylie technical
assistance department.
Bus Off
Verification of the bus CAN
controller.
1) There is a physical problem on the
CAN network..
Contact the RaycoWylie technical
assistance department.
Calib. parameter
The crane’s dimensions
must be correctly entered,
otherwise the load value
could be null or wrong.
The value of variables CL1, CL2 and
CL2MR should never be zero.
At power-up and during other processes, the i4000 system
analyzes all the interactions between the internal peripherals
(memories, controllers, extension boards) and the external
peripherals (physical boards connected with the CAN Bus
network). The system error indicator will appear on the main screen if an error is detected.
Содержание i4000
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 12: ......
Страница 17: ...17 i4000 Lattice Crane Instruction Manual 55M4000EBE00 Rev C 1 6 Overall scheme ...
Страница 28: ......
Страница 30: ......
Страница 57: ......
Страница 71: ...71 i4000 Lattice Crane Instruction Manual 55M4000EBE00 Rev C Notes ...
Страница 72: ......