Burners
Check that the burner has not gone to lock-out.
Causes of lock-out can be:-
l
No ignition, ignition electrode incorrectly positioned, insulation cracked, spark generator fault.
l
No oil supply.
l
Poor combustion.
l
Photo electric cell incorrectly positioned, cracked or needs cleaning.
l
Live and Neutral connections reversed.
l
Faulty control box.
l
Faulty fire valve.
l
Faulty relays.
REFER TO FLOW DIAGRAM FOR ELIMINATION PROCEDURE.
General
You can carry out some checks on the controls before you need to access the controls compartment behind the controls
door.
If only one of the burners is not running then the fault must be after the safety overheat thermostat.
Conversely of both the burners are affected then the fault lies before the programmer connections.
For access to individual controls refer to section Replacement Parts and for wiring continuity checks refer to Fig. 32 wiring
diagrams.
To check out the electrical wiring at the burners you will first have to access the burner chamber. Use the following
procedure:-
1. Isolate the electrical power supply.
2. Open up the bottom burner access door. Remove door and put in a safe place.
(Rayburn 680KCD C/F only).
3. Unscrew the 4 screws holding the inner panel in place and remove panel.
4. Unscrew the 3 screws holding the louvered plinth in place and remove plinth.
The external mains connections are made to a terminal block situated in the front left-hand corner of the burner chamber.
Re-connect the electrical supply and check that there is 230V power supply available across the mains input connection
L & N on the terminal block, if not then check connecting leads, fuses and whether power is available at mains plug.
Fault Finding
BURNER DOES NOT START
24
Содержание 680KCD C
Страница 9: ...Cleaning 9 Fig 6 ALL BAFFLES MUST BE STACKED IN PLACE AS DIAGRAM ABOVE ...
Страница 22: ...22 Fig 31 DESN 514774 Replacement of parts Electrical controls ...
Страница 23: ...23 Fault Finding Fig 32 Rayburn 600 700 Wiring Diagram 111MB for Individual Satronic boxes ...
Страница 29: ...Fault Finding 29 Fig 34A DESN 516838 ...
Страница 30: ...30 Fault Finding ...
Страница 31: ...31 Fault Finding ...
Страница 33: ...33 ...
Страница 34: ...34 ...
Страница 35: ...35 ...