WARNING: BEFORE REMOVING SERVICE ACCESS
COVERS OR THE OIL BURNER ENSURE THAT ALL
ELECTRICAL SUPPLIES TO THE APPLIANCE HAVE
BEEN ISOLATED.
The burners can be removed without disconnecting the oil
supply pipe. However if the filters are being cleaned or a
pressure gauge fitted to the pump then the oil supply
should be turned OFF and arrangements made to catch
any oil which will leak from the oil pump.
SEE FIG. 1
1.
Open up the bottom burner access door. Remove door
and put in a safe place.
(Rayburn 680KCD C/F only).
2.
Remove 4 inner panel securing screws and remove
panel.
3.
Remove the 3 plinth securing screws and remove
plinth.