SEE FIG. 15
Disconnect the flexible oil pipe line at the pump inlet, open
the stop valve slowly and run off some of the oil into a
receptacle to establish an air free supply to the pump. Re-
make the connection oil tight and leave valve open.
SEE FIG. 15
Remove the bleed screw from the manifold and fit an oil
pressure gauge with R1/8 connection to check the pump
output pressure.
Set the boiler burner time clock to continuous and turn the
boiler thermostat to maximum. The boiler burner should
run on pre-purge for 7-15 seconds. With the ignition spark
energised. The oil solenoid valve should open allowing
the burner to fire.
Until all the air from the oil pump is flushed out there may
be some flame instability, resulting in the burner locking
out. This will be shown by the burner stopping and the
illumination of the signal light in the reset button of the
control box (See Fig. 18).
IN THIS EVENT, WAIT AT
LEAST ONE MINUTE
, then press the re-set button to
restart.
SEE FIG. 18
Whilst the burner is running, vent air from the pump by
slackening the pressure gauge port sufficiently to allow air
to bleed out. When bubble free oil seeps out, re-tighten.
SEE FIG. 19
With the burner running check the oil pressure on the
pressure gauge.
If the pressure gauge is not indicating the correct reading,
then adjust the pressure by turning the pressure regulator
clockwise to increase or anti-clockwise to decrease the
pressure until the pressure gauge reads:
BOILER - 8.5 bar (125Ibf/In
2
)
COOKER - 10 bar (145Ibf/In
2
)
15
BLEED AIR FROM OIL SUPPLY
FIT PRESSURE GAUGE
SWITCH ON ELECTRICITY
VENT OIL PUMP
ADJUST OIL PRESSURE
Re-commissioning
Fig. 18
DESN 516263
BOILER BURNER
RESET BUTTON
PRESSURE PORT
BLEED SCREW
COOKER BURNER
RESET BUTTON
DESN 515912
Fig. 19
VACUUM
SUCTION
LINE
PRESSURE GAUGE
CONNECTION
PRESSURE
REGULATION
Содержание 680KCD C
Страница 9: ...Cleaning 9 Fig 6 ALL BAFFLES MUST BE STACKED IN PLACE AS DIAGRAM ABOVE ...
Страница 22: ...22 Fig 31 DESN 514774 Replacement of parts Electrical controls ...
Страница 23: ...23 Fault Finding Fig 32 Rayburn 600 700 Wiring Diagram 111MB for Individual Satronic boxes ...
Страница 29: ...Fault Finding 29 Fig 34A DESN 516838 ...
Страница 30: ...30 Fault Finding ...
Страница 31: ...31 Fault Finding ...
Страница 33: ...33 ...
Страница 34: ...34 ...
Страница 35: ...35 ...