SECTION 3
TECHNICAL DATA
HE 120N (T) Low Nox
TABLE 1/A
LPG (G 30 - G 31)
І
3+
-
П
2H3+
9
NOMINAL HEAT INPUT NET QMS
26.0 kW
MINIMUM HEAT INPUT NET
5.78 kW
NOMINAL HEAT OUTPUT
25.7 kW
NOMINAL HEAT OUTPUT CONDENSING
28.8 kW
MINIMUM HEAT OUTPUT
5.72 kW
MINIMUM HEAT OUTPUT CONDENSING
6.41 kW
GAS RATE
max G31 0.9 m
3
/h G30 0.7 m
3
/h
AFTER 10 MINUTES
min
0.4 m
3
/h 0.3 m
3
/h
INLET PRESSURE
G31 37 mbar G30 28-30 mbar
FAN SPEED C.H. Max 160 Hz Combusiton % CO
2
: G31 - 10.2 (+ 0.2 / - 0.5)
min 44 Hz with the Case OFF G30 - 11.0 (+ 0.2 / - 0.5)
BURNER INJECTORS
Nr. 1 x 5.6
ELECTRICAL SUPPLY
230 V ~ 50 HZ
POWER CONSUMPTION
160 W
EXTERNAL FUSE RATING
3A
INTERNAL FUSE
F1 - 3.15 A / F2 - 315 mA (20 mm to BS 4265)
DRY WEIGHT
40 kg
WATER CONTENT C.H.
2.0 litre
WATER CONTENT
0.5 litre
GAS SUPPLY CONNECTION
15 mm compression isolating valve
FLOW CONNECTION C.H.
22 mm compression isolating valve
RETURN CONNECTION C.H.
22 mm compression isolating valve
INLET CONNECTION D.H.W.
15 mm compression isolating valve
OUTLET CONNECTION D.H.W.
15 mm copper pipe
SAFETY DISCHARGE C.H.
15 mm copper pipe
CONDENSATION DRAIN
3/4” (21.5 mm) push fi t over fl ow
MAX COLD WATER CAPACITY WITHOUT ADDITIONAL EXPANSION VESSEL 110 LITRE
SEALED WATER SYSTEM C.H.
MAX PRESSURE PHS
2.5 bar
MINIMUM WORKING PRESSURE
0.5 bar
7 LITRES EXPANSION VESSEL PRE-CHARGE-PRESSURE
0.5 bar
CENTRAL HEATING OPERATING TEMPERATURE MAX 85°C min 40°C
DESIGN FLOW RATE 1383 I/h 20 °C RISE
MINIMUM FLOW RATE C.H. 503 I/min
D.H.W. FLOW RATE 30 °C rise
15.4 l/min
D.H.W. FLOW RATE 35 °C rise
13.2 l/min
D.H.W. FLOW RATE 40 °C rise
11.5 l/min 10°C inlet temperature
D.H.W. TEMPERATURE
Max 60 °C min 40 °C
FAN SPEED D.H.W.
Max 190 Hz
min 44 Hz
Qmw Input Net
Max 32.5 kW
min 5.78 kW
D.H.W. PRESSURE PMW
Max 10 bar (147 p.s.i.)
D.H.W. PRESSURE PMW
min 0.8 bar (118 p.s.i.)
To obtain heat input 1.2 bar
D.H.W. MINIMUM FLOW RATE
3 I/min
FLUE OUTLET NOM. DIAMETER 100 mm specially supplied with boilers (If required)
DESTINATION: BE, FR
CATEGORY I
3+
DESTINATION: GB, IE, CH, ES, IT, PT
CATEGORY II
2H3+
FLUE TYPE - C
13
- C
33
- C
53
NO
X
5
SEDBUK
A