8.26 TO REMOVE/REPLACE CONDENSING
TRAP (Fig.66).
8.26.1
Remove the casing (sect 8.1.4) and lower
the instrument panel .
8.26.2
Remove the securing clip and pull out the
plastic pipe that connect the condensing
trap at the heat exchanger.
8.26.3
Unscrew the nut that fasten the
condensing trap to the depression
chamber and remove it.
8.26.4
Replace in reverse order
Fig.67
8.28 TO REMOVE/REPLACE THE WATER
PRESSURE GAUGE (Fig. 67).
8.28.1
Remove front casing (sect 8.1.4)
lower
the instrument panel and remove
lower panel of the case.
8.28.2
Close the heating system on/off valves
and drain the water from the drain point
on the heating system .
8.28.3
Remove the retaining clip that secures the
pressure gauge probe.
8.28.4
Remove the pressure gauge from the
instrument panel by pressing its fastening
springs.
8.28.5
Replace in reverse order.
Fig.66
8.27
TO REMOVE/REPLACE THE MAIN
SWITCH (Fig. 67).
8.27.1
Remove front casing (sect 8.1.4) and lower
the instrument panel .
8.27.2
Remove the control box cover.
8.27.3
Pull off the switch knob. Remove
the switch out from the instrument panel
by pressing the clamp springs .
8.27.4
Detach the wires that connect to the
switch, make sure that these wires are
later reconnected to the same poles .
8.27.5
Replace in reverse order