CHAPTER 7
56
SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual
DIAGNOSTIC TROUBLE CODES (DTCS)
TABLE 2.
Diagnostic Trouble Codes
Code ID
Description
Recommended Actions
523152
31
Invalid pump state
Verify the communication setup/
shutdown alarm.
523154
9
Lost communication
Verify the communication setup/
shutdown alarm.
16
Target flow too high
1. Reduce the equipment speed.
2. Reduce the target application rate.
18
Target flow too low
1. Increase the equipment speed.
2. Increase the target application rate.
523160
1
Chemical tank is empty
Refill the product to continue field
applications.
17
Low tank volume remaining
Refill the product to continue field
applications.
523167
2
Injection pressure sensor
disconnected
1. Verify good connection to the pressure
sensor on the pump.
2. Verify the sensor is getting supply voltage.
3. Verify the signal voltage is getting back to
the pump ECU.
16
High injection pressure
1. Verify the communication setup/shutdown
alarm.
2. Check for an obstruction in the injection
system discharge hose.
3. Verify the carrier pressure is not exceeding
150 PSI.
523169
4
Low motor voltage
1. Verify high current breaker is not tripped.
2. Verify battery connections.
3. Verify speed sensor and signal. Refer to
the field computer operation manual for
information on testing speed and flow
cabling and troubleshooting the speed
sensor.